3
INSTALL TRIM
2
INSTALL DIVERTER (Models 5339.600/.602)
When finished tiling the wall, remove PLASTER GUARD
(1)
.
Remove two screws that secure the DIVERTER LID
(2)
and
remove Lid. Inspect the inside surface of diverter port.
Diverter port must be free of any dirt. Clean if necessary.
Install DIVERTER
(3)
with SCREWS
(4)
removed from
DIVERTER LID
(2)
.
Operate DIVERTER
(3)
. DIVERTER
(3)
should slide in
and out smoothly.
1
2
4
3
M968454A
DIVERTER
PORT
CAUTION: Protect finish on SHOWER HEAD and TUB SPOUT when installing.
Push on DIVERTER COVER
(1)
.
(Models 5339.600/.602)
Turn VALVE STEM
(9)
clockwise to off position.
Push CAP
(2)
on valve. Place ESCUTCHEON HOLDER
(3)
onto
CAP
(2)
and attach with LONG SCREWS
(4)
.
Place ESCUTCHEON
(5)
onto CAP
(2)
and attach with SHORT SCREWS
(6)
to ESCUTCHEON HOLDER
(3)
.
Push DECORATIVE RING
(7)
onto CAP
(2)
until seated flush against
ESCUTCHEON
(5)
. Push ADAPTER
(8)
onto VALVE STEM
(9)
and attach
to VALVE STEM
(9)
with SCREW
(10)
.
Align HANDLE
(11)
and thread onto ADAPTER
(8)
.
Screw DIVERTER KNOB
(15)
onto diverter stem.
(Models 5339.600/.602)
Remove pipe caps from rough-in nipples.
To install SHOWER HEAD
(12)
slide ESCUTCHEON
(13)
away from wall to expose
hex. Install SHOWER HEAD
(12)
and push ESCUTCHEON
(13)
flush with finished wall.
Thread TUB SPOUT
(14)
onto spout nipple.
14
2
3
5
7
8
10
11
4
9
1
12
15
6
Hot
Cold
Off
VALVE
PIPE CAP
PIPE CAP
13