background image

5339 Series

T339 Series

SHOWER

SYSTEM

VALVE

ONLY

B/S With

DIVERTER

BATH

FILLER

To assure proper positioning in relation to wall, note
roughing-in dimensions. 

ROUGHING-IN DIMENSIONS

Certified to comply with ANSI A112.18.1

Installation

Instructions

THREADED INLETS (STOPS)

INLETS

1/2" NPT

(13mm)

5-5/8" (143mm)

1-3/4"

(44mm)

OUTLETS 1/2" NPT (13mm)

5-5/8"

(143mm)

1

ROUGHING-IN

Turn off water at main supply.

CAUTION

When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS. When finished soldering,

flush valve body, replace cartridges, check stops and plaster guard to continue installation. Use thread

sealant or Teflon tape on threaded connections.

NOTE

If the valve is installed on a fiberglass
or other thin wall application, the
PLASTER GUARD 

(4)

 can be used as a support.

Connect hot and cold water supplies.
Cap off shower pipe 

(5)

 and tub filler pipe 

(6)

.

For support, use pipe BRACES 

(7) 

secured to wooden braces.

With valve turned off, turn on water supplies. Check for leaks.

COLD

HOT

Cut a 4" dia. hole in the shower stall.
Drill two additional 1" holes to allow access
to the stops.
Remove PLASTER GUARD 

(4)

, rotate 180˚

so that indicated screw holes fit MANIFOLD 

(2)

.

Push CAP on valve, place ESCUTCHEON on and
attach with screws.

1

7

5

3

6

4

2

See Roughing-in diagram before starting.
Connections are:
   1/2" female NPT for threaded inlets
Connect RISER PIPE 

(1)

 to MANIFOLD 

(2)

top outlet marked "SHR".
Connect TUB FILLER PIPE 

(3)

 at bottom

outlet marked "TUB".
For proper positioning the finished wall
must be within side wall of PLASTER
GUARD

 (4)

.

Recommended Tools

Flat Blade Screwdriver

Adjustable Wrench

Channel Locks

Plumbers' Putty or Caulking

Phillips Screwdriver

STEMMA

Thank you for selecting Porcher Products.

To ensure that your installation proceeds

smoothly--please read these instructions

carefully before you begin.

1-5/8" TO 3-1/4"

(41mm TO 83mm)

FINISHED WALL

BOTTOM OF

TUB

BOTTOM OF

TUB

74" FOR

HEAD CLEARANCE

(1880mm)

2-7/8" REF.

(73mm)

1/2" NPT (13mm)

1" (25mm)

OPTIONAL TO

FINISHED FLOOR 

USUALLY BETWEEN

65'' AND 78''

(1651 AND 2026mm)

8" REF.

(203mm)

4"

(102mm)

6-3/4"

(171mm)

7-1/2"

(191mm)

1/2" NPT (13mm)

18"

OPTIONAL

(457mm)

"SEE ILLUSTRATION"

NOTE:

 ALL DIMENSIONS

ARE TYPICAL TO B/S WITH

DIVERTER 

TOP OF

TUB RIM

TOP OF

TUB RIM

SHW

TUB

1" (25mm)

SHW

TUB

M968454A

Pipe Wrench

BATH/SHOWER WITH DIVERTER
SHOWER OR BATH FILLER ONLY

PRESSURE BALANCE

TEMPERATURE CONTROL VALVE 

Содержание 5339 Series

Страница 1: ...the stops Remove PLASTER GUARD 4 rotate 180 so that indicated screw holes fit MANIFOLD 2 Push CAP on valve place ESCUTCHEON on and attach with screws 1 7 5 3 6 4 2 See Roughing in diagram before starting Connections are 1 2 female NPT for threaded inlets Connect RISER PIPE 1 to MANIFOLD 2 top outlet marked SHR Connect TUB FILLER PIPE 3 at bottom outlet marked TUB For proper positioning the finishe...

Страница 2: ... STEM 9 clockwise to off position Push CAP 2 on valve Place ESCUTCHEON HOLDER 3 onto CAP 2 and attach with LONG SCREWS 4 Place ESCUTCHEON 5 onto CAP 2 and attach with SHORT SCREWS 6 to ESCUTCHEON HOLDER 3 Push DECORATIVE RING 7 onto CAP 2 until seated flush against ESCUTCHEON 5 Push ADAPTER 8 onto VALVE STEM 9 and attach to VALVE STEM 9 with SCREW 10 Align HANDLE 11 and thread onto ADAPTER 8 Screw...

Страница 3: ...nst top of casting Remove PRESSURE BALANCE UNIT 5 Rotate PRESSURE BALANCE UNIT 5 180 so that the inlets face up and the large outlet port faces down Push PRESSURE BALANCE UNIT 5 in casting make sure inlets line up with holes in bottom of casting Top flange should butt up against top of casting Reassemble FIXATION RING 4 and CARTRIDGE 1 UNABLE TO MAINTAIN CONSTANT TEMPERATURE 1 2 9 5 5 7 8 6 4 3 IN...

Страница 4: ...M STRAIGHTENER Replace the YYY with appropriate finish code A954440 0070A CARTRIDGE 023603 0070A CARTRIDGE SCREWS A923611 0070A HOT LIMIT STOP M961854 0070A FIXATION RING WITH SCREWS 051122 0070A SCREWDRIVER STOPS M952100 0070A PRESSURE BALANCING UNIT 027816 0070A 1 2 NPT PLUG 13mm BATH SHOWER WITH DIVERTER SHOWER OR BATH FILLER ONLY 5339 SERIES T339 SERIES Hot Cold Off A953929 0070A DIVERTER KIT ...