Setting
Description
900 - 65535
Seconds
0
disabled
Parameter 5: Temperature Upper Watermark value
This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2
Size: 2 Byte, Default Value: 0
Setting
Description
1 - 1000
1/10 degree
0
disabled
Parameter 6: Temperature Lower Watermark value
This parameter defines a temperature. If the measured temperature dropps below this watermark a BASIC command is sent into Association Group 3
Size: 2 Byte, Default Value: 0
Setting
Description
1 - 1000
1/10 degree (0,1°C - 100°C)
65336 - 65535
1/10 degree (-20,0°C - -0,1°C)
0
Disable
Parameter 7: Humidity Upper Watermark value
This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark a BASIC command is sent into Association Group 4
Size: 1 Byte, Default Value: 0
Setting
Description
10 - 100
%
0
disabled
Parameter 8: Humidity Lower Watermark value
This parameter defines a relative humidity. If the measured temperature dropps below this relative humidity a BASIC command is sent into Association Group 5
Size: 1 Byte, Default Value: 0
Setting
Description
1 - 90
%
0
disabled
Parameter 9: Low Temperature Trigger BASIC Set Command Value
This defines what BASIC command shall be sent out into association group 3
Size: 1 Byte, Default Value: 255
Setting
Description
0 - 255
Value
Parameter 10: High Temperature Trigger BASIC Set Command Value
This defines what BASIC command shall be sent out into association group 2
Size: 1 Byte, Default Value: 0
Setting
Description
0 - 255
Value
Parameter 11: Low Humidity Trigger BASIC Set Command Value
This defines what BASIC command shall be sent out into association group 5
Size: 1 Byte, Default Value: 255
Setting
Description
0 - 255
Value
Parameter 12: High Humidity Trigger BASIC Set Command Value
This defines what BASIC command shall be sent out into association group 4
Size: 1 Byte, Default Value: 0