Popp Flow Stop Скачать руководство пользователя страница 4

Its also possible to install the Flow Stop on a gas bottle as shown below.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be 

added to an existing wireless network

 to

communicate with the devices of this network. This process is called 

Inclusion

.

Devices can also be removed from a network. This process is called 

Exclusion

. Both processes are initiated by the primary controller of 

the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a 
special manual action right on the device.

Inclusion

press the red inclusion button 3 times. For Unsecure Inclusion press the red inclusion button 2 
times.

Exclusion

press the red inclusion button 3 times

Product Usage

The Flow Stop can be operated in three different ways. 

1.

Remotely using Z-Wave wireless on/off commands.

 The device will appear in your 

controller as a simple on/off switch easy to operate. To protect the device from tampering or 
wrongdoing you can limit the remote operations using the configuration parameter #1.

2.

Local operation by simple pushing the red button.

 Any push of the button will result in a 

change of the status from open to close or vice versa.

3.

Mechanical overwrite

 allows opening or closing the valve even in case of a power failure. 

Disconnect the valve using the internal clutch by pulling the ring. Keep the ring pulled while
moving the handle manually. Never move the handle without having the clutch 
disconnected. As best it will not work, as worst case it will destroy the device. Operating the 
valve manually only works without power supply. If the Flow Stop is powered and you 
operate the valve the motor will drive it into previous position immediately.

Node Information Frame

The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information
about the device type and the technical capabilities. The inclusion and exclusion of the device is 
confirmed by sending out a Node Information Frame. Beside this it may be needed for certain 
network operations to send out a Node Information Frame. To issue a NIF execute the following 
action: press the red inclusion button 3 times

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

Содержание Flow Stop

Страница 1: ...ll communicate with other devices secure as long as this device provides the same or a higher level of security Otherwise it will automatically turn into a lower level of security to maintain backward...

Страница 2: ...o only open or only close to further protect against malfunction Prepare for Installation Reset Please read the user manual before installing the product In order to include add a Z Wave device to a n...

Страница 3: ...ons to adapt the position of the flow stop on top of the valve 1 You can adapt the inner gap of the rocker arm 2 You can move the two mounting plates 3 You can change the distance of the two mounting...

Страница 4: ...operations using the configuration parameter 1 2 Local operation by simple pushing the red button Any push of the button will result in a change of the status from open to close or vice versa 3 Mecha...

Страница 5: ...ntain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the ev...

Страница 6: ...s capabilities and functions Support and Contact Should you encounter any problem please give us an opportunity to address it before returning this product Most questions regarding Z Wave wireless com...

Страница 7: ...es Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If el...

Отзывы: