34
13.
Troubleshooting Guide
Symptom
Cause
Remedy
Tool does not operate when switch
is pressed.
Battery is defective
Replace battery
Battery is not fully charged
Charge battery
Battery is not fully seated
Remove battery and re-insert. Reset
tool to home.
Battery pack has reached operating
temperature limit through
continuous use or defect.
Remove battery & allow to cool.
Mount battery and reset tool to
home.
Tool does not return to initial
position when switch is released.
Electrical malfunction.
Remove battery, wait 5 seconds and
reinsert. Reset tool to home.
Stuck Spindle Clutch.
Clean Spindle clutch and Spindle to
operate smoothly.
Tool stops before rivet is fully set
Battery pack has reached operating
temperature limit through
continuous use or defect.
Remove battery & allow to cool.
Mount battery and reset tool to
home.
Improper nosepiece selection.
Reset tool to home, remove rivet &
fit proper nose piece.
Setting load of rivet is beyond tool
capacity.
Reset tool to home, remove rivet &
use appropriate tool to set rivet.
Tool fails to operate
Issue with Trigger Module
Replace.
Tool does not return fully
Buildup of debris inside the Nose
Equipment.
Service and clean Nose Assembly.
More than one operation of the
trigger needed to place rivet
Buildup of debris inside the Nose
Equipment.
Service and clean Nose Assembly.
Worn or broken Jaws.
Fit new Jaws.
Improper rivet being used for
application grip thickness
Review application details and verify
fastener requirement
Jaw Guide or Pulling Head Adapter
not seated correctly.
Correctly assemble affected parts
Tool will not grip stem of rivet
Buildup of debris inside the Nose
Equipment.
Service and clean Nose Assembly.
Worn or broken Jaws.
Fit new Jaws.
Loose Jaw Guide.
Tighten jaw guide against Pulling
Head.
Week or broken Spring.
Fit new spring.
Incorrect Nose Piece for rivet.
Refer to Accessories Manual. Select
and install correct nose piece
Incorrect Nose Equipment for rivet.
Refer to Accessories Manual. Select
and install correct nose equipment
Jaws will not release broken stem of
rivet
Buildup of debris inside the Nose
Equipment.
Service and clean Nose Assembly.
Week or broken Spring.
Fit new spring.
Jaw Guide, Nose Piece or Nose
Housing not seated correctly.
Correctly assemble affected parts
Stem retention/removal feature worn
out on Nose Piece
Inspect Nose Piece and replace O-ring
and ball/pin as required
Cannot insert rivet
Incorrect Nose Piece for rivet.
Refer to Accessories Manual. Select
and install correct nose piece