24
5. Operation
5.4 Antifreeze protection
5.5 WiFI
Configuration
When the heat pump is on standby, two antifreeze modes can be activated depending on the weather
conditions.
The system monitors the ambient temperature and the water temperature to activate the anti-freeze pro
-
gram if necessary.
First antifreeze system:
When the outside temperature is lower than 2 ° C, the system starts the circulation pump for 5 minutes
every 40 minutes. when the water outlet temperature is less than 4 ° C, the circulation pump starts automa-
tically.
Second antifreeze system:
If the outdoor temperature is below 2 ° C and the water temperature is below 4 ° C, the heat pump switches
to heating mode until the water temperature is above 15 ° C. or the ambient temperature is above 8 ° C.
When the pump is in antifreeze mode, an E04 error is displayed if the water outlet temperature is less than
2 ° C. This code disappears when the outlet water temperature exceeds 4 ° C.
In the main interface, tap on the WiFi logo.
- «Smart configure»
this mode allows you to intelligently configure the WiFi connection. Once this mode is activated, the “WiFi”
logo flashes. Launch your Tuya Smart application on your phone and connect to your heat pump.
- «AP Configure»
This mode creates a WiFi Hotspot. Connect your smartphone to the heat pump HotSpot then launch your
Tuya Smart application.
Find more information in the WiFi manual dedicated to the Tuya Smart application at:
www.poolex.fr
WARNING: For the antifreeze system to work, the heat pump must be powered and the
circulating pump activated. If the circulating pump is servo-controlled by the heat pump,
it will be automatically activated.