5
5. MAINTeNANCe ANd INSPeCTION
5.3 Guide for Poor Heat Gain
POOL WATER IS NOT HEATING UP:
• Is the heat pump turned on ?
• What is the temperature set too ?
• Is there sufficient water flow ?
• How long is the heat pump set to run for ?
• Are there any water features ?
• Does the pool have a blanket ?
• What is the ambient temperature ?
• Is the condenser covered in ice ?
• Are bypass valves closed off ?
NOTE: IF THE CONDENSER IS COVERED IN ICE
Set the parameter 02 to 30 minutes
Set parameter 03 to 0
Set parameter 05 to 15 minutes
5.4 Customer Responsibilities
BEFORE YOU CALL FOR SERVICE
read the following points carefully which are your responsibility.
• A service charge will be made for service as a result of:
• Power not turned on or disrupted
• Heat pump not set to run for a long enough period
• Heat pump installed incorrectly
• Recirculation pump not operating correctly
• Controls incorrectly set
• Poor water chemistry (Salt Level, pH, etc)
• Poor water flow (Check filter is clean/Pump operation/Skimmer free of obstructions and bypass flow is not excessive)
• Heat pump being tampered with by unauthorized persons
• Excessive ambient conditions