17
MESSAGE
DISPLAYED/FAULT
DETECTED
IMMEDIATE
AUTOMATIC STOP
POSSIBLE CAUSE
CHECKS AND REMEDIES
OPTION TO
DISABLE VIA
THE ‘
Settings -
Alarms
’
menu
Chlorine
dosing
pH
regulation
Alarm
CL injection
Yes
No
Series of
unsuccessful
attempts to
correct the
chlorine
concentration
•
Check the chlorine container is
not empty.
•
At the chlorine injection circuit,
check the condition of the:
-
filter with ballast.
-
semi-rigid pipes.
-
injection pump.
-
injection connector.
•
Manually inject chlorine.
Check that:
-
the pump is working properly.
-
chlorine is correctly injected.
•
Check the settings in the ‘
Dosing
–
CL setpoint
’ menus.
•
Carry out an adjustment of the
free chlorine rate measurement.
No
Alarm
pH injection
No
Yes
Series of
unsuccessful
attempts to
correct the pH
•
Ensure
the
pH
corrector
container is not empty.
•
At the pH corrector injection
circuit, check the condition of
the:
-
filter with ballast.
-
semi-rigid pipes.
-
injection pump.
-
injection connector.
•
Manually inject pH corrector.
Check that:
-
the pump is working properly.
-
the pH corrector is correctly
injected.
•
Check the settings in the ‘
pH
Regulation
–
Setpoint
’ menus.
•
Calibrate the pH probe.
No