15
MESSAGE
DISPLAYED /
FAULT
DETECTED
IMMEDIATE
AUTOMATIC ACTION
CAUSE
CHECKS AND REMEDIES
OPTION TO
DEACTIVATE
VIA THE
MENU
«
»
Stopping
production
Stopping
pH
regulation
Yes
Yes
Insufficient water flow
through the filtration
circuit.
Check that :
the flow sensor is connected
to the electronics unit.
the flow sensor is activated
(«
»
menu).
the valves on the filtration
circuit are open.
the filtration pump is
working correctly.
the filtration circuit is not
blocked.
there is enough water in the
pool.
No
Yes
No
Loss of communication
between the control
board and the power
board of the electronics
unit.
Contact a professional.
No
No
Yes
pH probe incorrectly
calibrated.
Carry out a calibration of the
pH probe.
Yes
No
Yes
Series of 5 unsuccessful
attempts to correct the
pH.
Ensure the pH corrector
container is not empty.
Carry out a manual injection
(menu «
»).
Check the condition of the
filter with ballast and
injection connector.
Check the settings in the
«
»,
«
»
and «
»
menus.
Carry out a calibration of the
pH probe.
Yes
Yes
Yes
Insufficient amount of
water in the filtration
circuit.
Check that the filtration pump
is running correctly.
Yes
Yes
No
ORP measurement out of
tolerance for 24 hours
(difference of ± 400 mV
compared to the ORP
setpoint).
Carry out a «
».
Carry out a calibration of the
ORP probe.
Go to the «
» menu and check
that the production setpoint
is at 100 %.
Yes