- 37 -
Controller state table
Screen
Explanation
Check
Solution (if no reset)
St-by
Stand-by
-
-
FLO
No water flow or the flow switch
doesn’t detect the water flow
- Check if filtration pump is
working.
- Check by-pass setting.
- Check water flow switch position.
Contact your seller
AL10 / AL11
HP error
AL15 / AL16
Too much temperature difference
between water in and water out.
AL18
Comp. Out temp. Too high
AL17
Low temp protection in cooling
mode
AL7 / AL8
Communication error
Check
electrical
connection
between controller and electronic
card inside the machine.
AL3
Probe error (Water in)
Check probe connection.
AL4
Probe error (Water out)
AL5
Probe error (coil.)
AL1
Probe error (comp. out)
AL2
Probe error (comp. in)
AL6
Probe error (ambiance)
AL9
Fan error
Check fan connection.
AL14
Outdoor temperature too low
Outdoor temp is below 0°C
Wait
for
the
outdoor
temperature to increase.
AL19 / AL20
Power supply problem
Ask an electrician specialist to
check power supply.
Contact your seller
AL21 / AL22 / AL23 /
AL24 / AL25
Electronic/overheating protection
Stop the power supply for 5 to 10
minutes, check that air flow is not
blocked, turn ON power supply
Water flow setting
To optimize the performance of the heating process, it is advisable to regulate the water flow through the pool heat
pump.
The adjustment must be carried out according to the indication given by the pressure gauge. The setting is modified by
opening or closing the setting valve of the by-pass.
To increase the pressure on the manometer (pressure gauge), the water flow passing through the heat pump must
decrease:
Open the setting valve.
To decrease the pressure on the manometer (pressure gauge), the water flow passing through the heat pump must
increase:
Close the setting valve.
For a normal working performance, inlet and outlet valves must be completely open.
Normal pressure
Pressure inside the refrigerant circuit of the heat pump and the water flow influence each other.
To work correctly, a water flow of 5 to 7 m³/h (100 l/min) should be maintained for maximum heat transfer.
Ideal by-pass setting is obtained when the manometer needle indicates (when working in heating boost Hi mode for
several minutes) a temperature between 10 to 15°C higher than the swimming pool water temperature.
Warning: The Heat pump needs to operate for few minutes before the internal pressure stabilizes
Содержание EcoSpec 09 Silent Inverter
Страница 1: ...Handbook EcoSpec Silent Inverter 21 0 FR GB docx EcoSpec Silent Inverter FR...
Страница 13: ...13 R glages cran Luminosit et langues des messages d erreur Informations Informations cran...
Страница 21: ...21 EcoSpec Silent Inverter EN...
Страница 33: ...33 Screen setting Luminosity and error messages language Informations Informations screen...
Страница 41: ...41 EcoSpec Silent Inverter ES...
Страница 53: ...53 Ajuste pantalla Iluminaci n mensajes de error idioma Informaci n Informaci n pantalla...
Страница 61: ...61 EcoSpec Silent Inverter DE...
Страница 73: ...73 Bildschirmeinstellungen Helligkeit Fehlermeldungen Sprache Information Bildschirminformation...