- EN -
15
Opening the UCV clarifying unit (F)
•
Remove the cover from the UVC clarifying unit.
•
Turn the UVC clarifying unit counter-clockwise up against the stop (bayonet closure), then carefully pull out of the filter
cover including the O ring (1).
•
Loosen the self-tapping screw (7) until the the screw tip is sunk in the housing of the clamping screw (2).
•
Unscrew the clamping screw counter-clockwise (3).
•
Remove the quartz glass including the O ring towards the front with a slight turning movement (4).
•
Check the quartz glass and the O ring for damage and replace, if necessary.
•
Clean the quartz glass outer face with a moist cloth.
Replacing the UVC lamp (F)
Important:
Only use lamps the identification and capacity data of which correspond to the information on the type
plate.
For an optimum filter performance, we recommend to replace the UVC lamp after approx. 8,000 operating hours.
•
Pull out and replace the UVC lamp.
Assembly of
the UVC clarifying unit (F)
•
Insert the quartz glass including the O ring against the stop in the unit head (6).
•
Press the O ring into the gap between unit head and quartz glass.
•
Tighten the clamping screw clockwise up to the stop (7).
•
Tighten the self-tapping screw (8).
•
Check the O-Ring at the unit head for damage and replace, if necessary (9).
•
Carefully push the unit head into the housing while applying slight pressure. Ensure that the tenons at the housing
engage in the grooves of the bayonet closure.
•
Turn the unit head clockwise against the stop while applying slight pressure.
•
Refit the cover for the UVC pre-clarifying unit.
Cleaning the filter pump (G)
Take pump out of the water, unscrew the stepped hose connection including the 12 x 4 mm O ring from the connection
thread (G1), actuate the engagement hook of the filter housing (G2), open the filter housing and remove the pump
(G4). Turn off the pump housing, remove the impeller (G5). Clean the pump housing, the impeller and the filter housing
(G3) using clear water and a brush. After cleaning, fit the unit in the reverse order (G6-G7).
Storage/Over-wintering
Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to be
expected. Drain and thoroughly clean the pressure filter, check for damage. Remove, clean, dry and store all filters in a
frost-free environment. Store the filter pump submerged or filled in a frost-free environment. Do not immerse the plugs!
Ensure that the storage place is inaccessible to children. Cover the filter container such that the ingress of rain water is
excluded. Drain all hoses, pipes and connections as far as possible.
Wear parts
•
Filter media
•
UVC lamp, quartz glass and O ring for quartz glass
•