PA460Bi-C Power Amplifier User Manual
2
1. Safety Precaution
Read User Manual before operation.
1. Check carefully all buttons are positioned correctly before startup.
1) Pause button in correct position in pressed state.
2) ON/OFF in OFF state.
3) Not press high power button (High power indicator in OFF state)
2. Main supply capacity should meet the requirement; otherwise it will affect output power
of amplifier during high current output.
3. Handle the amplifier with great care and follow the symbols on the package: fragile,
handle with care, top (an arrow pointing up), keep dry and protect from shaking.
4. Generally it’s not necessary to depress high power button (high power button light
should be off also).
5. Never operate live signal and load wires with current output to protect the safety of
equipment and personnel.
6. In case the power outlet for powering up the amplifier does not have protective
ground customer must connect the ground socket to the protective ground at the
test site
7. The voltage output of over 36V is considered as dangerous and care must be
taken
8. It’s not allowed to feed external voltage into the current output sockets
9. It’s not allowed to feed external current into the current output sockets
10. Disconnect the external circuit from the relay to avoid any influence to the test
11. Do not block the ventilation outlets