5.1 Detector for hose leakages
The hose leakage detector is for a continuous monitoring in order to avoid unnoticed hose
leakages.
Functional description
In case of a hose leakage the pump can be switched off and an alarm (horn/signal lamp)
can be activated. This is only possible when using a motor contactor.
The following mentionned detectors for hose leakages are available:
art.-no. 93-000-055
Detecor for hose leackages for operating the pumps in non-hazardous locations and for
electrically conductive media.
art.-no. 93-000-009
Detector for hose leackages for operating the pumps in hazardous locations and for
electrically non-conductive media.
art.-no. 93-000-045
Detector for hose leackages with SPC sensor for operating the pumps in non-hazardous
locations.
pump
horn
light
sensor