background image

 

 
 
 
 
 
The termination to the mains supply should be permanent, inside a dry weatherproof 
enclosure, through a double pole switched fused spur with a minimum contact gap of 3mm – 
(disconnected) to BS 3676 – and fitted with a 3 or 5 amp fuse. 
Exposed cable runs should be sensibly positioned, and protected if necessary by armoured 
conduit. A 10mA or 30mA Residual Current Circuit Breaker (RCD) MUST be fitted to the 
mains supply. Permanent installations to the mains supply (hard wiring) must comply with 
the regulations of the local electricity authority which may stipulate the use of metal or 
plastic conduit to protect the cable. If in any doubt about wiring to the mains supply contact 
a qualified electrician or your local electricity authority. 
 

Directions for use 

These outdoor lights can be used in or out of the water. 
If used out of water take care to make sure no objects touch or are left too close to the lights 
as they get extremely hot in use. When used submerged it is best to place the unit approx 1 
foot below the water surface (at deeper levels brightness is reduced). 

 

Certain models may include 

a dawn-to-dusk sensor

. You can test your lights are working 

by covering the sensor with your finger (replicating darkness). This clever feature ensures 
your lights come on when it gets dark and go off at sunrise. 
 

Changing the coloured lenses

 

Simply unscrew the light cap as shown on the light itself. 
Remove the lens in position and replace with required colour. 
Re-assemble the end cap by rotation. 
 

Limited Warranty 

This product is guaranteed for a period of 12 months from the date of purchase for material 
or manufacturing defects. The guarantee covers the substitution of defective parts. However, 
the guarantee is considered null and void in the case of improper use, improper handling or 
negligence on the part of the buyer. The bulbs are not guaranteed. If your pondXpert light 
fails please take it back to the retail outlet from where it was purchased. You will be 
required to take your receipt/proof of purchase with you. 
This does not affect your statutory rights. 
PondXpert 
A3 Bentley Avenue 
Billingham 
TS23 4BU 
UK 

 

01642 370898         www.pondxpert.co.uk 

The wires in the mains electrical lead are coloured in accordance with the 
following code: 
BLUE – Neutral (marked with an “N” in most terminal connections) 
BROWN – LIVE (marked with an “L” in most terminal connections) 
GREEN/YELLOW – EARTH (marked “E” or       in most terminal connections) 

1

st

 January 2005 revised Building Regulations for England and Wales 

Installing this product in the garden is classified as ‘notifiable’. The 
Regulations now require you to tell your local authority building control 
department that you intend to install this product before installation. Your 
local authority will let you know how you can get your installation approved 

 

Your appliance 
contains valuable 
materials which can 
be recovered or 
recycled.  Leave it at 
a local civic waste 
collection point. 

Отзывы: