background image

WAT E R G A R D E N I N G   T O   T H E   M A X

CLEAR WATER 

KIT

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT SAFEGUARDS

PMAX FP Series Pump Instruction Manual .indd    3

March 2021

Page 3

WAT E R G A R D E N I N G   T O   T H E   M A X

 TM

Please read the operating instructions and familiarize yourself with the equipment before placing it 

in service. Correct and safe use of the equipment requires strict compliance with the safety instructions.

For safety reasons persons less than 16 years of age or people that are not familiar with these 

instructions should not use this equipment.

 

 

 

 

 

 

 

 

 

 

The appliance power supply cable must form an 

appropriate loop, facing downwards (Fig. 4, Page 7), 

to prevent any runoff water from coming into contact 

with the socket itself.

Do not place the supply cable underground, but  follow 

the installation instructions prescribed by the local 

regulations in force, and consult a qualified installer 

and electrician.

When installing the appliance, do not use the supply 

cable to lift it.

Before starting up the appliance, check that it has 

been correctly installed.

Do not make any technical alterations to the appliance. 

Use only original spare parts and accessories.

The maximum temperature for the circulating liquid 

must not exceed 95°F (35°C).

WARNING: Avoid exposure to direct sunlight. Do not use 

or keep the appliance in an area subject to freezing. 

In winter, it is necessary to remove, empty and 

position the appliance so that it is protected.

The appliances must not be operated dry. Do not use 

these appliances for filtering caustic, abrasive,

inflammable, aggressive or explosive liquids, and 

even drinking water.

WARNING: Never look directly at the UVC9W lamp 

when it is switched on.

WARNING: The PondMAX® UVC9W Water Clarifier 

contains glass. Handle with care.

WARNING: Never connect the filters to the public 

water supply network.

WARNING: The PondMAX® UVC9W Water Clarifier 

must not operate immersed in water. If they should 

accidentally fall into it, before recovering them, 

disconnect the plugs from the power supply socket. 

Take the same care if you should notice that any parts 

of the appliance are wet.

 

 

 

 

WARNING: Both appliances (PondMAX® FP550 Pump

and PondMAX® UVC9W Water Clarifier) cannot be used

by children under 8 or persons with reduced physical, 

sensory or mental capabilities, or lack of experience 

and knowledge, unless they have been given 

supervision or instructions concerning use of the 

appliance in a safe way and understand the risks 

involved. Children shall not play with the appliance 

because this is not a toy. Cleaning and maintenance 

shall not be made by children without supervision. 

Children shall not play with the appliance because 

this is not a toy. Cleaning and maintenance shall 

not be made by children without supervision.

WARNING: Disconnect all submerged electrical 

appliances in the pond before carrying out 

installation and maintenance operations. If the 

connection plug or the electric socket should 

be wet, disconnect the main switch before 

disconnecting the power supply cable.

The power cord cannot be repaired. If it is 

damaged, the entire appliance must be discarded. 

Only for the PondMAX® UVC9W Water Clarifier 

it is possible to replace the power cord with a 

cord of the same kind. BUT THIS OPERATION 

MUST BE PERFORMED BY QUALIFIED

PERSONNEL ONLY.

These appliances must be supplied through a 

residual current device (RCD) having a rated 

residual current not exceeding 30mA (Idn ≤ 30 mA).

WARNING: The PondMAX® UVC9W Water Clarifier 

contains an emitter with UVC9W rays, which 

may damage the eyes and skin. Improper 

use or damage to their protective casing may 

cause harmful UVC9W radiations. If clearly 

damaged, the appliances must not be used.

WARNING: It is prohibited to use the UVC9W 

lamp on the outside of the appliance.

Check that the voltage given on the appliance 

label corresponds to the mains voltage.

Before connecting the appliance to the mains, 

check that the cable and the appliance are 

not damaged in any way.

Содержание UVC9W

Страница 1: ...CLEAR WATER KIT INSTRUCTION MANUAL PondMAX USA 888 868 1185 www pondmax com DATE MARCH 2021 v1 0 MODEL CW1800 PMAX FP Series Pump Instruction Manual indd 1 March 2021 TM ...

Страница 2: ...R CODE 23UV009 PondMAX CW1800 Clear Water Kit Filter Tank DIMENSIONS CW1800 PRODUCT ORDER CODE 23CW018 15 5 x 11 5 x 15 5 40 x 29 x 40 cm KIT INCLUDES FILTER TANK TANK LID FINE FILTER SPONGE BLUE COARSE FILTER SPONGE BLACK BIO SPHERE MEDIA SPRAY BAR OVERFLOW PIPE WATER PUMP PondMAX FP550 WATER CLARIFIER PondMAX UVC9W KINK FREE HOSE HOSE BARBS FITTING ACCESSORIES PondMAX FP550 Pump MAX WATER FLOW G...

Страница 3: ...rate immersed in water If they should accidentally fall into it before recovering them disconnect the plugs from the power supply socket Take the same care if you should notice that any parts of the appliance are wet WARNING Both appliances PondMAX FP550 Pump and PondMAX UVC9W Water Clarifier cannot be used by children under 8 or persons with reduced physical sensory or mental capabilities or lack...

Страница 4: ...ining ring Clamp ring Safety screw Unlock button Filter head Filter head O ring Screw nozzle of UV C filter O ring for UV C threaded coupling models with UV C Intermediate coupling for mounting of UV C filter spray bar UV C models B C D E F G H I L M Cord 3 4 Spray bar Accessories for mounting UV C filter filter body 6a Internal side of the filter box screw washer O ring 6b External side of the fi...

Страница 5: ...tered water into the pond it is necessary to use the kink free hose with the required diameter taking into account that 2 adaptors included into the package allow mounting of hoses with diameter 1 or 1 1 4 25mm or 32mm Fig 6 Page 7 PondMAX FP550 PUMP PondMAX UVC9W Water Clarifier 1 Insert the elbow adaptor Exploded view 12 Page 4 into the corresponding screw ring 2 Connect the end of one of the 2 ...

Страница 6: ...FILTER TANK MAINTENANCE USE OF PUMP AND UV C WATER CLARIFIER INCLUDED IN KIT For complete assembly maintenance and warranty information of the PondMAX FP550 Pump and PondMAX UVC9W Water Clarifier included in PondMAX CW1800 Clear Water Kit please refer to each individual Instruction Manual included with the kit WARNING The PondMAX FP550 Pump can operate both immersed into the pond and outside the p...

Страница 7: ...arch 2021 Page 7 WAT E R G A R D E N I N G T O T H E M A X CW1800 CLEAR WATER KIT MAINTENANCE CLEAR WATER KIT OUTLET INLET FOR HOSES HOSE CONNECTOR Ø 20 25 mm Fig 6 UVC9W Fig 5 DRIP LOOP Fig 5 Fig 4 Fig 7 PUMP MIN 6 5 FT 2 M PUMP SUBMERSIBLE USE PUMP EXTERNAL USE MIN 6 5 FT 2 M MIN 6 5 FT 2 M ...

Страница 8: ...lbow at inlet 1 with internal thread for hose ø 20 mm Fine filter sponge blue Coarse filter sponge black Bio sphere media PONDMAX CW1800 CLEAR WATER KIT PARTS DESCRIPTION No 1 2 3 4 5 6 7 8 9 10 REPLACEMENT PARTS REFER TO UVC WATER CLARIFIER INSTRUCTION MANUAL INCLUDED PONDMAX UVC9W WATER CLARIFIER PARTS DESCRIPTION 2 3 4 5 9 8 7 1 6 REFER TO FP PUMP INSTRUCTION MANUAL INCLUDED PONDMAX FP550 PUMP ...

Отзывы: