INSTALLATION

For your convenience we have provided a built in flow control on the Front Filter Screen. This can be used to adjust 

the water flow if the flow is too fast for a particular installation. These are mainly used in clean water features with no 

debris. 

• It is advised, that when used in an outdoor environment, to integrate an optional PondMAX SP250 

Submersible Prefilter, to provide additional pre-filtration and to protect the pump (

 at your local 

dealer).  

PRODUCT SPECIFIC SAFEGUARDS 

• Do not operate the pump without water at any time, 

permanent damage may occur.

• Pond & Fountain pumps are a magnetically driven 

pump. Be sure the equipment is submerged 
completely in the water. If used externally, the pump 
must have adequate flooded suction at all times, 
therefore they cannot suck from a water level that is 
below the inlet level.

• The pump is designed to be used for ponds, fountains 

and other fresh water features.

• The pump should only be used in clean water only. 

Do not use the pump in, or with, any chemicals such as 
a solvent or gasoline. 

• All PondMax Pond & Fountain pumps are cooled by 

water flowing through the inside of the motor body. 
If the pump flow becomes restricted it will overheat 
and could cause permanent damage. Large tubing size 
is strongly recommended to deliver adequate water 
flow to cool the pump. The pump needs to be cleaned 
regularly to prevent the pump becoming blocked, thus 
causing the pump to overheat and burn out. This is not 
a warrantable event. It is strongly recommended not to 
select a pump that is too small for the job required. The 
flow rate through the pump needs to be enough so 
that a half of the rated max flow is kept running at all 
times. 

PLUMBING GUIDE

SUBMERSIBLE USE

• When used inside a pond /fountain 

follow 

 as outlined below. 

• For best results, consult with an expert to make sure 

you use the correct size of tubing for your pump flow 
and application.

•  Select the outlet hosetail 

 and screw into the 

top of the pump. 

• Now connect the tubing to the hosetail. Remember to 

use stainless steel hose clamps to fasten the hose  

EXTERNAL USE

When installed outside the pond or fountain, follow 

proceedure as outlined below.

• For best results in external applications, the pump 

must have adequate flooded suction at all times 
(installed outside pond or fountain, below elevation of 
the surface of water). Also consult with an expert to 
make sure you use the correct size of tubing for your 
pump flow and application.

• In external applications it is necessary to remove the 

Front Filter Screen and Sponge from the pump to 
expose the threaded inlet. Do this by removing the 
front filter screen from the front of the pump. Push 
in the two tabs on either side of the filter screen and 
pull away from pump. NOTE: You will not need either 
the Front Filter Screen or Sponge in an external 
application, so feel free to keep with this instruction 
manual or discard.

• Select the inlet and outlet hosetail 

 and screw 

into both ports on the pump. 

• Now the pump is ready to be connected to new or 

existing plumbing configuration. Extra fittings and 
adapters may be required (

 at your local 

dealer), based on the specific application.

• Make sure that the suction line (inlet side of plumbing) 

has a suction screen or leaf strainer to catch large 
debris that could potentially harm pump (ask your 
local dealer for further information).  

FOUNTAIN KIT SET UP GUIDE

PondMAX offers optional fountain kits that correlate 
with these pumps. For suggestions on the correct model, 
see the specification table on page 2 of this manual.

• NOTE: For the purpose of these guidelines, a PondMAX 

#30 Jet kit has been selected below as a sample. The 

installation principle will be similar for the other types. 

P O N D M A X . C O M

Содержание PV250

Страница 1: ...VERSION AUG 2022 22PV030 PV250 22PV050 PV350 22PV075 PV550 POND FOUNTAIN PUMP INSTRUCTION MANUAL 888 868 1185 info pondmax com www pondmax com ...

Страница 2: ...BEFORE USING THIS PRODUCT PLEASE READ THESE INSTRUCTIONS CAREFULLY AND BECOME FAMILIAR WITH THE UNIT PLEASE KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE SUBJECT TO VARIATION ACCORDING TO LOAD SOLD SEPARATELY DESIGN HIGHLIGHTS The PondMax Pond Fountain Pumps have been manufactured to provide you with the best quality pumps for your water feature Visit our website to view our range o...

Страница 3: ...ect If required have a qualified electrician install a weatherproof power supply point near to the pond or water feature within the cable length of the appliance Be sure the equipment is submerged completely in the water The depth should not be greater than 6 5Ft Do not operate the pump if the appliance or any components of the system such as the power cable have been damaged Check appliance for d...

Страница 4: ...tain follow as outlined below For best results consult with an expert to make sure you use the correct size of tubing for your pump flow and application Select the outlet hosetail and screw into the top of the pump Now connect the tubing to the hosetail Remember to use stainless steel hose clamps to fasten the hose EXTERNAL USE When installed outside the pond or fountain follow proceedure as outli...

Страница 5: ...ce 2 onto the threaded portion of 1 2 Nipple Now on the top of the Dual Control T Piece 2 connect the Threaded Reducing 4 on Now extend Telescopic Riser with Threaded Locking Nut 10 to the desired height then secure onto the top 1 thread of the Threaded Reducing with the threaded locking nut provided Align Telescopic Riser with Threaded Locking Nut 10 vertically 7 Fine Daisy Fountain Nozzle 8 Coar...

Страница 6: ...reassemble in the reverse manner Reinstall the shaft and then carefully slide the impeller onto the shaft The impeller will pull itself in by magnetic force this is normal Take care not to pinch your fingers With the impeller in the correct position carefully place the impeller cover back on and then rotate clockwise to lock into position Making sure the ceramic shaft is located properly in the im...

Страница 7: ...d filter media blocked with sludge Clean the sponges and filters Impeller is blocked with sludge or lime scale build up Clean the impeller as per the instructions Submerse the equipment underwater then plug in Refill if necessary Blocked impeller chamber or ceramic shaft is broken Clean the impeller Check for wear Replace if necessary WATER PUMP IS NOISY Blockage in pump Clear the blockage Impelle...

Страница 8: ...Company at 888 868 1185 or on the Company s website www pondmax com This Limited Warranty does not cover defects caused by non compliance with Company s use guides care guides and or instruction manual Such failures include but are not limited to exposure to physical abuse including but not limited to chemical abuse e g harsh cleansers and solvents thermal abuse or shock e g excessive heat or cold...