EXPLODED VIEW

10 

1  

Front FIlter Screen

Sponge

Flow Control Knob

Volute Assembly

O-Ring

Impeller Assembly

Pump Motor Body

Suction C p Feet x4

3/4” Barbed Adapter for Inle

1/2” Barbed Adapter Fitting

5

9

10

11

1

2

3

4

6

7

8

IMPORTANT NOTES

• It is important that this procedure is carried out 

regularly as the cooling path inside the motor could 
become clogged. If the impeller assembly becomes 
worn or damaged it should be replaced (available from 
your dealer or special order). Failure to do so may 
cause serious damage to pump motor. Inspect for 
signs for wear and tear. The impeller set is a wearing 
consumable part. Replace if necessary. 

• Once the cleaning and inspection process is 

completed, reassemble in the reverse manner. Reinstall 
the shaft, and then carefully slide the impeller onto the 
shaft.  

The impeller will pull itself in by magnetic force, this 
is normal. (Take care not to pinch your fingers). With 
the impeller in the correct position, carefully place 
the impeller cover back on, and then rotate 
clockwise to lock into position. Making sure the 
ceramic shaft is located properly in the impeller 
cover center hole.

• Then reinsert the internal sponge back into the 

filter cage and reattach to the pump or reattach 
optional prefilter, which ever is applcable to your 
application.

• Reattach tubing/fountain kit, submerse in water. 

IMPORTANT

These accessories and attachments are recommended for use with your PondMAX product specified in this manual. The use of any other accessories or attachments 
might present a risk of injury to persons. Only use the accessory or attachment for its stated purpose.

4

PMAX PV250_350_550 Pump Instructions.indd   6

28/9/16   9:50 am

P O N D M A X . C O M

Содержание 22PV030

Страница 1: ...ERSION SEPT 2016 22PV030 PV250 22PV050 PV350 22PV075 PV550 POND FOUNTAIN PUMP INSTRUCTION MANUAL 888 868 1185 info pondmax com www pondmax com PMAX PV250_350_550 Pump Instructions indd 1 28 9 16 9 50 am ...

Страница 2: ...SE READ THESE INSTRUCTIONS CAREFULLY AND BECOME FAMILIAR WITH THE UNIT PLEASE KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE SUBJECT TO VARIATION ACCORDING TO LOAD SOLD SEPARATELY DESIGN HIGHLIGHTS The PondMax Pond Fountain Pumps have been manufactured to provide you with the best quality pumps for your water feature Visit our website to view our range of pond filtration outdoor unde...

Страница 3: ...ed electrician install a weatherproof power supply point near to the pond or water feature within the cable length of the appliance Be sure the equipment is submerged completely in the water The depth should not be greater than 6 5Ft Do not operate the pump if the appliance or any components of the system such as the power cable have been damaged Check appliance for defects regularly For safety pl...

Страница 4: ...For best results consult with an expert to make sure you use the correct size of tubing for your pump flow and application Select the outlet hosetail and screw into the top of the pump Now connect the tubing to the hosetail Remember to use stainless steel hose clamps to fasten the hose EXTERNAL USE When installed outside the pond or fountain follow proceedure as outlined below For best results in ...

Страница 5: ... of 1 2 Nipple Now on the top of the Dual Control T Piece 2 connect the Threaded Reducing 4 on Now extend Telescopic Riser with Threaded Locking Nut 10 to the desired height then secure onto the top 1 thread of the Threaded Reducing with the threaded locking nut provided Align Telescopic Riser with Threaded Locking Nut 10 vertically 7 Fine Daisy Fountain Nozzle 8 Coarse Daisy Fountain Nozzle 9 Bel...

Страница 6: ...er Reinstall the shaft and then carefully slide the impeller onto the shaft The impeller will pull itself in by magnetic force this is normal Take care not to pinch your fingers With the impeller in the correct position carefully place the impeller cover back on and then rotate clockwise to lock into position Making sure the ceramic shaft is located properly in the impeller cover center hole Then ...

Страница 7: ...udge Clean the sponges and filters Impeller is blocked with sludge or lime scale build up Clean the impeller as per the instructions Submerse the equipment underwater then plug in Refill if necessary Blocked impeller chamber or ceramic shaft is broken Clean the impeller Check for wear Replace if necessary WATER PUMP IS NOISY Blockage in pump Clear the blockage Impeller shaft worn out Replace impel...

Страница 8: ... this warranty This warranty is in lieu of all other express warranties which now or hereafter might otherwise arise with respect to this product Any and all limited warranties including the warranties of merchantability and fitness for particular purpose shall have no greater duration than the duration period of the express written warranty applicable to this product and shall terminate automatic...

Отзывы: