Pondmaster 02710 Скачать руководство пользователя страница 3

CAUTION

 

The pump is intended to pump water only. It cannot be used to pump oil, solvents, or gasoline. Although the pump will continue to 

run if there is no water, after 30 minutes damage may occur if allowed to run dry. 

ZG120 Rev.D 1

2/16

CARE AND OPERATING INSTRUCTIONS FOR  MAGNETIC DRIVE 2-7 PUMPS 

ITEM # 02512, 02513, 02515, 02517, 02522, 02523, 02525, 02527 

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

used with inline piping note the following: Centrifugal pumps cannot pull water from a lower level. In order to start, pump must be below 

water level and filled with water. Unless the air can escape from the outlet, the pump will not start. Do not use glues or solvents to connect 

the pumps threaded fittings. Use Teflon pipe tape. The pump cover is not designed to support long pipe runs or to correct pipe misalignment. 

To remove the base, strike with moderate force in the direction toward the pump cover. The latch will bend and the base will slide off the 

housing. To attach the base, slide the base (latch first) on the pump cover side of the housing. Slide the base onto the dovetail mounting 

tracks until the latch snaps.

SERVICE AND MAINTENANCE

 

The pump cover should occasionally be removed to clean and inspect the impeller assembly. The impeller is the only serviceable item and 

can be pulled out of the body . Do not take the impeller apart except for cleaning when used in salt water or hard water applications; see 

below. If it is worn or broken the entire impeller assembly should be replaced. This will restore the pump to original capacity. Pumps taken out 

of service for an extended period with fluid inside run the risk of forming a crust which may prevent subsequent starting. Saltwater should 

be flushed out with fresh water. Always check cord for sharp bends  which can  cause  premature cracking. Do  not  use  power cord to  lift 

or move pump. Other than Impeller assembly, this appliance has no user serviceable parts.

IMPORTANT: FOR PUMPS USED IN SALTWATER OR HARD WATER

Magnet impeller assembly must be routinely removed for cleaning with Pumpguard

TM 

(sold separately)

 to remove accumulations of scale  or 

calcium. This procedure should be done at least once every three months - or more often if the water conditions require it. 

 

Disassemble magnet from impeller by pulling them apart (it may take a strong pull). One end cap will come off. To clean the calcium scale 

off the shaft and bearing inside of the magnet, soak in Pumpguard. Rinse and reassemble magnet / impeller assembly. Do not lose any 

washers  located between the end cap and impeller.

Pondmaster Pumpguard - 4oz. (#03905), 32 oz (#03907), 1gal. (#03909)

Supreme Pumpguard for Aquarium - 4oz. (#40770), 32 oz (#40771), 1gal. (#40773)

Supreme Pumpguard for Hydroponics - 4oz. (#06331), 32 oz (#06335)

IMPORTANT SAFETY INSTRUCTIONS

WARNING – To guard against injury, basic safety precautions should be observed, including the following:

a)

READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

b) DANGER – To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For

each of the following situations, do not attempt repairs by yourself; return the appliance to an authorized service facility for service or discard 

the appliance:

1) If the appliance shows any sign of abnormal water leakage, immediately unplug it from the power source. (Immersible equipment only)

2) Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not intended to be wet.

3) Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or has been dropped or damaged in any manner.

4) To avoid the possibility of the appliance plug or receptacle getting wet, position aquarium stand and tank to one side of a wall-mounted

receptacle to prevent water from dripping onto the receptacle or plug. A “drip loop,” shown in the figure below, should be arranged by the

user for each cord connecting an aquarium appliance to a receptacle. The “drip loop” is that part of the cord below the level of the

receptacle, or the connector if an extension cord is used, to prevent water traveling along the cord and coming in contact with the recep-

tacle. If the plug or receptacle does get wet, DON’T unplug the cord. Disconnect the fuse or circuit breaker that supplies power to the

appliance. Then, unplug and examine for presence of water in the receptacle.

c) Close supervision is necessary when any appliance is used by or near children.

d) To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs,

and the like.

e) Always unplug an appliance from an outlet when not in use, before putting on or taking off

parts, and before cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to

disconnect.

f) Do not use an appliance for other than intended use. The use of attachments not recommended

or sold by the appliance manufacturer may cause an unsafe condition.

g) Do not install or store the appliance where it will be exposed to the weather or to temperatures

below freezing.

h) Make sure an appliance mounted on a tank is securely installed before operating it.

i) Read and observe all the important notices on the appliance.

j) If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than the appliance

rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.

PUMP

POWER 

SUPPLY 

CORD

WATER 

TANK

 DRIP 
LOOP

RECEPTACLE

This appliance should be grounded to minimize the possibility of electric shock. This 

appliance is equipped with an electric cord having an equipment grounding 

conductor and a grounding type plug. The plug must be plugged into an outlet that 

is installed and grounded in accordance with all appropriate codes and ordinances. 

This appliance is for use on a nominal 120-volt circuit, and has a grounding plug  that 

looks like the plug illustrated in (A) below. A temporary adapter which looks like the 

adapter  illustrated in (B) and (C) below may be used to connect this plug to a two-pole 

receptacle as shown in (B) if a grounded outlet is not available. The temporary adapter 

should be used only until a grounded outlet can be installed by a qualified electrician. 

The green-colored rigid ear (lug, and the like) extending from the adapter must be 

fastened to a permanent ground such as a grounded outlet box.

GROUNDING INSTRUCTIONS

METAL

SCREW

COVER OF 

GROUNDED 

OUTLET BOX

ADAPTER

GROUNDING 

MEANS

GROUNDING 

PIN

(A)

(B)

(C)

Содержание 02710

Страница 1: ...t plug To reduce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle Always use a properly grounded outlet Do not immerse plug in water DO NOT REACH INTO WATER TO REMOVE PLUG TURN OFF CIRCUIT FIRST A drip loop should be provided The drip loop is a loop in the cord below the level of the receptacle or plug that prevents water from traveli...

Страница 2: ...ZG100 rev D 11 16 02718 RIGID PREFILTER and COLLAR 12785 12785 12785 ASSEMBLY ...

Страница 3: ...d service facility for service or discard the appliance 1 If the appliance shows any sign of abnormal water leakage immediately unplug it from the power source Immersible equipment only 2 Carefully examine the appliance after installation It should not be plugged in if there is water on parts not intended to be wet 3 Do not operate any appliance if it has a damaged cord or plug or if it is malfunc...

Страница 4: ...MP NEAR ELECTRICAL CORD MODEL 2 MODEL 3 MODEL 5 MODEL 7 WATER LEVEL HEAD HEIGHT IS MEASURED FROM WATER SURFACE PUMP SUBMERSION LEVEL 40 MAX in AQUARIUMS MODEL COMPLETE PUMP FOAM RIGID BASE PUMP COVER IMPELLER COVER PREFILTER PREFILTER 3 4 BARB INLET MODEL 2 12555 12535 12505 12784 12515 12536 MODEL 3 12575 12535 12505 12784 12515 12536 MODEL 5 12575 12545 12505 12784 12515 12546 MODEL 7 12585 1254...

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ...400 3600 2000 3000 1800 2800 1400 2400 20 24 1 MPT 1 MPT 1 FPT 1 FPT 265 360 3 0 3 0 02740 40140 MD24 10FT CORD AQUARIUM UTILITY PUMP 02745 MD36A 10FT CORD AQUARIUM UTILITY PUMP 02750 PM 24 18FT CORD POND 02755 PM36A 18FT CORD POND ITEM ITEM Looking for dependable patio decoration Rely on Pondmaster for quality and long lasting products ...

Отзывы: