LIMITED WARRANTY 

 

All pumps and electrical products are warranted to the user against defective material and workmanship, under 
normal working conditions.  This warranty period begins on the date of purchase by the original purchaser.   
 
Unless otherwise specified all pond boss® electrical products are warranted to the user against defective 
material and workmanship, under normal working conditions for 1 year from the date of purchase.   

 

Pond and Waterfall pumps are warranted for 3 years.   

 

All pond boss® liners are warranted to the user against defective workmanship, under normal working 
conditions for 20 years from the date of purchase.   

 

All other pond boss® products are warranted to the user against defective material and workmanship, 
under normal working conditions for 90 days.   

 

Application 

Warranty covers only properly installed and maintained units.  Any damage to the cord or modification to the unit 
will invalidate the warranty.  Pump warranty is limited to applications pumping fresh water in a pond or fountain 
only.  Other liquid applications or extreme temperature uses must be approved in writing by the manufacturer.  
Receipt and product date code are required for warranty claims. 
 

Warranty Claim 

Warranty claims must be made by calling customer service (at 1-888-755-6750).

  If the item is determined 

to be defective, you will be given authorization to return the defective part(s), freight pre-paid, along with proof of 
purchase. 
 

 

Disposition 

The manufacturer will make a good faith effort for prompt disposition regarding all warranty claims.  Returned 
product will be inspected to determine cause of failure before warranty is applied.  Warranty does not cover any 
costs associated with the shipping, handling, installation or removal of products or parts subject to this warranty.  
For products damaged in transit, a claim should be filed with the carrier. 

 

Disclaimer 

Any oral statements made about the product by the seller, the manufacturer, the representatives, or any other 
parties do not constitute warranties, should not be relied upon by the user, and are not part of the contract for 
sale.  The seller’s and manufacturer’s only obligation, and buyer’s only remedy shall be for the manufacturer to 
either replace and/or repair at the manufacturer’s sole discretion, the product as described above.  Neither seller 
nor the manufacturer shall be liable for injury, loss or damages for lost profits, lost sales, injury to person or 
property, or any other incidental or consequential loss arising from any cause whatsoever, no matter whether 
based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy 
shall be available to them. Before using, the buyer and user shall determine the suitability of the product for the 
intended use, and assume all risk and liability whatsoever in connection therewith.  The warranty and remedy 
described in this limited warranty is an exclusive warranty and remedy in lieu of any other warranty or remedy 
expressed or implied.  All other warranties and remedies are hereby expressly excluded, including but not 
limited to any implied warranty of merchantability of fitness for any particular purpose.  This warranty gives the 
buyer and user specific legal rights, and buyer and user may also have other rights which vary from state to 
state.  Some states do not allow exclusions or limitations of incidental or consequential damages, so the above 
limitations or exclusions may not apply to you. 
 

REMINDER 

CALL 1-888-755-6750 

BEFORE RETURNING TO STORE.

 

  

 

Содержание PW1250

Страница 1: ...g Risk of electrical shock This pump has not been investigated for use in swimming pools or marine areas CAUTION This pump has been evaluated for use with water only Use a proper power source as indicated on the pump label Keep the cord away from high temperatures or other heat sources Do not pump heated liquids Do not let the pump run dry Pump must be completely submerged for proper operation and...

Страница 2: ...w OPERATION INSTRUCTIONS 1 For maximum water flow it is recommended that the largest tubing size for your pump is used If using 1 in ID tubing proceed to step 2 If using 1 1 2 in ID tubing cut the adapter as shown using a hacksaw Fig 1 Fig 1 2 Connect tubing to the outlet of the pump using an adapter Fig 2 NOTE Tubing is NOT INCLUDED Fig 2 3 Place the pump inside the pump barrier bag Pull the draw...

Страница 3: ...ic force resisting the extraction of the impeller assembly This is normal Likewise when replacing the impeller assembly there will be a strong magnetic force pulling the assembly into the pump to potentially cause injury to fingers and in rare cases damaging the ceramic shaft or rear bearing Use thick gloves when replacing the impeller assembly Use a soft cloth or brush to clean the impeller assem...

Страница 4: ...ail us at customercare thepondboss net PUMP PERFORMANCE FLOW RATES LIFT FEET 14 220 GPH 13 330 GPH 12 440 GPH 11 550 GPH 10 660 GPH 9 780 GPH 8 900 GPH 7 1 000 GPH 6 1 100 GPH 5 1 200 GPH 4 1 300 GPH 3 1 400 GPH 2 1 490 GPH 1 1 580 GPH 0 1 650 GPH PW1250 Printed in China Part Description B 1 in and 1 1 2 in ID tubing adapter C pump barrier bag D Impeller housing E O ring F Impeller Assembly G Scre...

Страница 5: ... warranty is applied Warranty does not cover any costs associated with the shipping handling installation or removal of products or parts subject to this warranty For products damaged in transit a claim should be filed with the carrier Disclaimer Any oral statements made about the product by the seller the manufacturer the representatives or any other parties do not constitute warranties should no...