Type WE6s32
WK 420 970 05.2018
- 2 -
WE6.../...H...
8
P
P
P
P
7
Version WE6…/O
O
O
O… ---- only for spools: A
A
A
A,
C
C
C
C, D
D
D
D, EA
EA
EA
EA, GA
GA
GA
GA, HA
HA
HA
HA, JA
JA
JA
JA, MA
MA
MA
MA, EB
EB
EB
EB, GB
GB
GB
GB, HB
HB
HB
HB, JB
JB
JB
JB, MB
MB
MB
MB.
2-position directional spool valve without
return springs. The spool is positioned and
supported with attached solenoid. There is
no neutral position as the spool is not
positioned.
Version WE6…/…B
B
B
B… - directional spool
valve designation like that, has throttle
insert (7) in port P
P
P
P.
Directional control valve type WE6
WE6
WE6
WE6… is also available in
versions with optional equipment: manual operation
lever (8) - version WE6.../...H
H
H
H… - see page 10 to 11;
manual operation lever with a lock (9) - version
WE6.../...HF
HF
HF
HF… - see page 12 to 15 or/and inductive
sensor of spool position control (10) type S
SS
S - version
WE6.../...- S
SS
S - see page 18 to 20; inductive sensor of spool
position control (11) type M
M
M
M - version WE6.../...- M
M
M
M - see
page 21 to 23.
D
D
D
DC
C
C
C
Degree of pr
Degree of pr
Degree of pr
Degree of pr o
o
o
otecti
tecti
tecti
tectio
o
o
on
n
n
n
I
I I
IP
P
P
P 6
6
6
65
5
5
5
2
2
2
23
3
3
30
0
0
0V
V
V
V----50Hz 2
2
2
22
2
2
20
0
0
0V
V
V
V
- 50Hz 1
1
1
11
1
1
10
0
0
0V
V
V
V
- 50Hz
1
1
1
12
2
2
2V
V
V
V 2
2
2
24
4
4
4V
V
V
V 1
1
1
11
1
1
10
0
0
0V
V
V
V
2
2
2
23
3
3
30
0
0
0V
V
V
V---- 50Hz
A
A
A
AC
C
C
C
direct supply
±10%
Holding power (AC)
Switch-on power (AC)
50 VA
300 VA
_
_
Viscosity range
Ambient temperature range
mineral oil
Hydraulic fluid
Nominal fluid viscosity
2
o
37 mm /s at temperature 55 C
2
2,8 up to 380 mm /s
recommended
max
Fluid temperature range (in a tank)
40 C up to 55 C
o
o
-20 C up to +70 C
o
o
- 20 C up to +50 C
o
o
Re
Re
Re
Req
q
q
qu
u
u
uired f
ired f
ired f
ired fllllu
u
u
uid c
id c
id c
id cle
le
le
lea
aa
an
n
n
nlllliiiine
ne
ne
ness c
ss c
ss c
ss clllla
aa
ass
ss
ss
ss
IIIISSSSO
O
O
O 4
4
4
44
4
4
40
0
0
06 c
6 c
6 c
6 clllla
aa
ass
ss
ss
ss 2
2
2
20
0
0
0////1
1
1
18
8
8
8////1
1
1
15
5
5
5
port
port
port
port T
TT
T 21
21
21
21 M
M
M
MP
P
P
Pa
aa
a
port
port
port
ports P
s P
s P
s P
, A
A
A
A
, B 35
B 35
B 35
B 35 M
M
M
MP
P
P
Pa
aa
a
M
M
M
Ma
aa
ax
xx
xim
im
im
imum
um
um
um oper
oper
oper
operat
at
at
atiiiing pres
ng pres
ng pres
ng presssssure
ure
ure
ure
Flow section for spool W
W
W
W
in central position
(diagrams on page 5)
3 % nominal flow
with 1 solenoid WE6...- 1,5 kg WE6...
H
H
H
H
...- 2,8 kg
with 2 solenoids WE6...- 2,1 kg WE6...
H
H
H
H
...- 3,4 kg
Switching time
Maximum switching frequency
Weight
15000 on/h
S
SS
Supp
upp
upp
upply
ly
ly
ly v
vv
vo
o
o
olt
lt
lt
ltage
age
age
age o
o
o
of s
f s
f s
f so
o
o
ole
le
le
len
n
n
no
o
o
oid
id
id
idssss
Supply voltage tolerance
±10%
Power requirement (DC)
30 W
Solenoid coil temperature max 150 C
o
ON up to 60 ms
OFF up to 40 ms
A
A
A
AC
C
C
C
(plug-in connector with rectifier)
12000 on/h
ON up to 40 ms
OFF up to 25 ms
_
TECHNICAL DATA
WE6.../...- S
WE6.../...- M
WE6.../... HF...
11
10