Pompetravaini TCHM Series Скачать руководство пользователя страница 2

Disassembly & assembly instructions single stage centrifugal pumps series TCHM & TCTM 

INTRODUCTION 

 

These  instructions  are f or the m aintenance per sonnel f or m aintenance and/or  r epair of  the indic ated pum p s eries. 

Disassembly and assembly require expertise and k nowledge of the procedures, therefore the work must be carried out 

by qualified personnel. 

These instructions must be carefully read and understood in conjunction with the section drawings and tables contained 

in the manual and enclosed, prior to attempt any work on the pumps. 

For s afety, ins tallation and m aintenance ins tructions c onsult the  manual  “INSTALLATION  &  OPERATING 

INSTRUCTIONS  FOR CENT RIFUGAL PUMPS” attac hed to the  pump at tim e of  s hipment. Cons ult als o any  other 

attached ins tructions f or ac cessories and/or  c omponents inc luded w ith the pum ps s uch  as  mechanical  seals,  heat 

exchangers, flushing systems, instrumentation, etc. 

Before  operating  or  working  on the pum p it is  r ecommended to adopt s afety pr ecautions w earing s afety attir e ( hat, 

glasses, gloves, shoes, etc.) and have ready the necessary tools required for the work to be done. 

Do not subject the pump of its components to sudden mechanical impacts and /or distortions. 

Do not damage or scratch the sealing faces. Pay particular attention not to damage flat gaskets and O-Rings. 

Careful not to leave foreign matters such as moults, screws, washers, rags, etc. in the pump. 

When requesting spare parts or technical information for the pum p, always quote the pum p model number and s erial 

number which is printed on the pump nameplate: therefore it is recommended not to remove the pump nameplate or, in 

case this action will be necessary, write the serial number on the pump (for example on the flange). 

Should additional inf ormation be r equired, pleas e do not hes itate to c ontact PO MPETRAVAINI or  the  closest 

representative. Should there be any difficulties in repairing the pump, it is recommended to send the pump for repair to 

POMPETRAVAINI or the local authorised representative. 

Pump r epairs and/or  s ervice c arried out by  c ustomer or  unauthor ised per sonnel ar e not guar anteed by  

POMPETRAVAINI

 

or by its subsidiaries. 

Note:  Pump parts list identify all pump components by item number (VDMA) in connection with the sectional drawings. 

All dr awings ar e f or r eference pur pose and not  are  certified f or c onstruction, how ever s hould additional 

information be required, contact POMPETRAVAINI or its closest representative. 

 

INDEX 

 

1  -  Steps to be followed prior to pump disassembly 
2  -  Disassembly and assembly 

 2.1 

- Disassembly 

 2.2 

- Assembly 

3 -  Spare 

parts 

4 -  Section 

drawings 

5  -  Nomenclature of pump parts 
6 -  Engineering 

tables 

 

 

The liquids handled by the pum ps and als o their parts could be potentially dangerous for persons and 

environment:  provide their  eventual  disposal in c onformity w ith the law s into f orce and a pr oper 

environment management.

 

 

 

The present manual is not as signed for pumps subjected to  the ATEX 94/9/CE directive. In case the 

pump is assigned in environments  subjected to the application ATEX 99/92/CE directive or in case the 

pump is provided with a nam eplate indicating the AT EX stamp, it s trictly forbidden proceed to start up 

the pumps but necessary to consult POMPETRAVAINI for clarifications. 

For pumps subjected to the ATEX 94/9/CE directive it is available a dedicated integrative manual.

 

 

 

In preparing this manual, every possible effort has been made to help the customer and operat or with the proper i nstallation and operation of the 

pump. Should you find errors, misunderstandings or discrepancies please do not hesitate to bring them to our attention. 

 

 

 

1 - STEPS TO BE FOLLOWED PRIOR TO PUMP DISASSEMBLY

 

 

Should pum p r epairs be r equired, it is  r ecommended to ac quire f ull f amiliarity of  the pr ocedures  to  be  followed  by 

studying these instructions and the “Operating Manual for Centrifugal Pumps”. 

 

 

FOLLOW T HE SAFET Y  INSTRUCTIONS LIST ED UNDER CHAPT ER 2 OF T HE AFORE MENT IONED 

OPERATING MANUAL.

 

 

Содержание TCHM Series

Страница 1: ... Rev 2 0_10 2010 DISASSEMBLY ASSEMBLY INSTRUCTIONS SINGLE STAGE CENTRIFUGAL PUMPS TCHM TCTM ...

Страница 2: ... difficulties in repairing the pump it is recommended to send the pump for repair to POMPETRAVAINI or the local authorised representative Pump r epairs and or s ervice c arried out by c ustomer or unauthor ised per sonnel ar e not guar anteed by POMPETRAVAINI or by its subsidiaries Note Pump parts list identify all pump components by item number VDMA in connection with the sectional drawings All d...

Страница 3: ... the pump assembly Remove the nuts from studs VDMA 902 1 remove casing cover VDMA 161 from lantern flange VDMA 341 Particular care should be given w hen removing the m echanical seal components from the pum p mechanical seals are fragile and may easily get damaged when mishandled Remove the stationary mechanical seal face from the casing cover replace if necessary For complete pump disassembly pro...

Страница 4: ...nary seal face Seal m ust be suitable for clockwise rotation unless it is a bi directional type Slide and locate the seal locating ring in the original location which had been m arked or at the m easured location then tighten the two set screws To prevent seal damages and br eakdowns it is recommended not to us e excessive force when fitting the seals their components can be fragile ONLY FOR TCHM ...

Страница 5: ...902 2 183 902 1 904 320 433 2 932 932 1 542 901 1 341 901 210 Fig 1 Pump series TCHM gr 1 and 2 design 1 C Single mechanical seal and motor frame 80 and 90 421 925 940 2 230 161 102 903 3 562 400 1 903 1 485 902 2 932 1 902 1 904 320 433 2 932 183 542 901 1 341 901 210 110 Fig 2 Pump series TCTM gr 1 and 2 design 1 C Single mechanical seal and motor frame 80 and 90 ...

Страница 6: ...2 Mechanical seal bush 183 Suppor t foot 562 Pin 210 Shaf t 901 Screw 230 Im peller 902 Stud 320 Ball bearing 903 Plug 341 Lanter n 904 G rub screw 400 1 Gasket 925 Impeller locking nut 421 Radial seal ring 932 Circlip 433 2 Mec hanical seal 940 Key 6 ENGINEERING TABLES Fig 3 Torque values for various bolt sizes Torque values Nm 300 200 100 20 50 15 30 40 60 70 80 150 4 6 8 10 12 14 16 18 20 22 24...

Страница 7: ... 72 84 13 0 33 0 48 0 43 0 58 6 25 160 72 84 13 0 33 0 48 0 43 0 58 6 25 200 72 84 13 0 33 0 48 0 43 0 58 5 32 125 72 84 13 0 33 0 48 0 43 0 58 6 32 160 72 84 13 0 33 0 48 0 43 0 58 5 32 200 72 84 13 0 33 0 48 0 43 0 58 5 32 250 85 97 13 0 44 0 59 0 74 0 89 6 40 125 85 97 13 0 34 0 49 0 44 0 59 10 40 160 85 97 13 0 34 0 49 0 44 0 59 7 5 40 200 85 97 13 0 34 0 49 0 44 0 59 6 40 250 95 110 16 0 44 0...

Страница 8: ... at 1 m Pressure dB A Power dB A INSTALLATION SERVICE Ins ide O utside Continuous Inter mittent Ex plosive area MOTOR type Frame No Poles No Revolutions RPM Absorbed power Amp Installed Power kW HP Frequency Hz Supply Volt Enclosure IP Insulation class Absorbed Power kW HP COMMENTS NA5 SM TCHM GB00 PRINTED IN ITALY Smontaggio TCHM TCTM Inglese POMPETRAVAINI S continuing research results in product...