8. General programming
Upon powering up, the device runs through an internal routine and all channels (4 for PCU 4131 and 8 for
PCU 8130) are set to the current stored data. During this time, the
Status LED
flashes green.
A connection between the PCU 4131 / PCU 8130 and the PC / notebook can only be established after the
Status LED lights up permanently green or orange.
8.1. Initial setup
The PCU 4131 / PCU 8130 are configured via the Network Management System (NMS).
8.1.1. Establishing a connection via the browser
Connect the PC or notebook directly to the network management port using a suitable CATx LAN cable.
The input window appearance depends on the selected browser (Chrome, Firefox, Internet Explorer, etc.).
Notes:
PC / notebook and the IP streamer must be in the same network / IP address range.
Cookies must be accepted and JavaScript must be enabled.
Use current browser versions.
Enter the following IP address in the search bar of the web browser:
192.168.1.129
Username:
admin
Password:
password
Then click
OK
to establish the connection.
If the factory IP address of the IP streamer is lost or forgotten, it can be reset to the factory setting
(
192.168.1.129
) as follows:
Pull the mains plug out.
Press and hold button TA1 on the IP board.
Reconnect the mains plug.
Wait until the Status LED flashes red / green alternately.
Now the IP address is reset and the button can be released.