- 9 -
6-3. Global gain
Global gain (analog gain) can be configured with the standard viewer software or SDK.
The formulas for the setting value and gain are as follows.
MODEL
METHOD
ARTCAM-130UV-WOM /
ARTCAM-092UV-WOM
Setting range: 0 to 11 (x3 to x24)
Setting value: between 0 and 6 -> Gain = value + 3
Setting value: between 7 and 11 -> Gain = (value – 3) * 3
Ex)
When setting value is 0 -> 0 + 3 = 3
[x3 gain]
When setting value is 11 -> (11 - 3) * 3 = 24
[x24 gain]
6-4. Trigger Input (For 130UV-WOM)
ARTCAM-130UV-WOM has an external trigger input circuit insulated by a photo coupler.
Therefore, the camera can take pictures using external trigger.
Trigger Input Circuit
R1 = 2.4kΩ (5~12V)
R2 = 10.0kΩ
R2
TRIG
3.3V
FPGA
Camera
R1
BNC
TLP290(SE