background image

3

Model:

 

UFH4ZW

Installation

The UFH4ZW can be mounted directly to a wall using four screws or 
alternatively, the unit can be DIN rail mounted.

When DIN Rail mounting, you first need to insert the two clips 
provided on the back of the UH4, as shown in the image;

 

• 

 On the back of the UFH4ZW, position the clip in the middle 

 

and slide down.

 

• 

 Points A and B locate in the corresponding holes and  
lock into place.

 

• 

 Locate the UFH4ZW onto the DIN rail from the top.

 

• 

 Pull the clip down and push the bottom of the UFH4ZW onto 

 

the DIN rail.

 

• 

 Releasing the clip will lock the UFH4ZW in place on the DIN rail.

To remove the UFH4ZW, pull both clips down and remove from the DIN rail.

B

A

Insert clip here.

Then Slide down to lock in place.

Содержание UFH4ZW

Страница 1: ...Model UFH4ZW...

Страница 2: ...is also included as standard This is the pump valve Output which would normally operate a manifold pump or a manifold valve The H W output provides a 230v hot water enable signal to the valve the auxi...

Страница 3: ...ge On the back of the UFH4ZW position the clip in the middle and slide down Points A and B locate in the corresponding holes and lock into place Locate the UFH4ZW onto the DIN rail from the top Pull t...

Страница 4: ...als marked L are the same and both terminals marked N are the same Each zone output corresponds to the thermostat wired in at the top of the pcb Connections Mains Supply Power supply into the UFH4ZW w...

Страница 5: ...ough a high limit switch placed on the heating manifold to protect against mechanical failure of the manifolds temperature control Fuses Fuse 1 5amp 20mm anti surge fuse this fuse supplies power to al...

Страница 6: ...derfloor Heating 1 x Radiator zone Hot Water Manifold Valve Pump connections This equipment should be installed by an appropriately Fully read the instructions for proper wiring before applying power...

Страница 7: ...MS N N N N N N N N N N 1 A 1 A 1 A 1 A A1 2 T R 2 T R 2 T R 2 T R 1 T R 1 T R 1 T R 1 T R 2 T R 2 A 2 A 2 A 2 A 1 T R A2 L S L S SL SL SL ZONE 3 HOT WATER ZONE 4 ZONE 2 ZONE 1 L L L L L E E E E L L E...

Страница 8: ...ONE 1 MAINS L E N L E N SL L L N N ZONE 2 ZONE 2 L E N SL L L N N L E N LS E LR UFH4ZW Polypipe 230v Thermostat Wiring This equipment should be installed by an appropriately Fully read the instruction...

Страница 9: ...THROUGH THE CYLINDER HIGH LIMIT THERMOSTAT ACTUATORS 230V UFH HEATING HOTWATER SmartStat ZONE 3 ZONE 3 L E N SL L L N N ZONE 4 ZONE 4 L E N SL L L N N HOT WATER HOT WATER VALVE L E N SL L E N GR OR Ra...

Страница 10: ...Wiring Centre 10 System Configuration PLEASE COMPLETE DURING INSTALLATION UFH4ZWTitle In Use ZoneType ZoneTitle Under Floor Radiator Zone 1 Zone 2 Zone 3 Zone 4 HotWater...

Страница 11: ...11 Model UFH4ZW Notes...

Страница 12: ...ipe Building Products Broomhouse Lane Edlington Doncaster DN12 1ES Want More Information Call our telephone support team on 01709 772200 Or view technical specifications directly on our website www po...