Email:
3
Website:
www.polypipe.com/ventilation
LAB1107R, Issue 3, August 2015
Wiring Instructions:
It is recommended that the fans are connected into the lighting circuit, with double pole isolation (3mm minimum
contact separation) provided before the room light switch and suitably fused, in accordance with the latest edition of
the IEE Wiring Regulations.
Wall mounted fans for fixed wiring should be connected to the power supply through a cable with solid conductors of
1.0mm² or 1.5mm².
ONLY GCF100LV SELV MODELS ARE SUITABLE FOR SHOWER CUBICLES OR ZONES 1 & 2
(IN THIS RANGE)
WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK
IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN
SL = 230Vac Switched Live
L = 230Vac Permanent Live
N = Neutral
T = 12VDC
+ = 12VDC
- = 0VDC
GCF100LV-S
GCF100LV-HPC (auto humidity only)
GCF100LV-T
GCF100LV-HPC (optional timer operation
operating switch not required)
Diagram 4