7 Technical Specification
8 Fault Diagnostics
07
6 Hidden Menu
There is a hidden installer menu which can be accessed by
pressing and holding a combination of buttons.
The user menu can be used to set a number of user preferences
such as a 12 hour or 24 hour clock display. And also used to
adjust various operational settings of the unit.
To access this menu set the unit to the setting and press and
hold the ( ) button for 10 seconds.
PB4ZCTC
Hidden Installer Menu
Menu No
Display
Description
Default
Option
00
Ch INI
Sets number of
required channels
N/A
1 to 4
Channels
01
dEG
Change temp
display between
degC or degF
Deg C
Deg F
02
Time
24H
Change between
12H or 24H
clock display
24H
12H
03
dSt
Yes
Automated
clock change for
Daylight Saving
Time
YES
No
05
AirS
Current room
temperature
N/A
None
06
AirC
Air temperature
calibration
N/A
None
07
SENS Err
No remote
sensor detected
N/A
Function
not active
08
SENC
Remote sensor
calibration
N/A
Function
not active
09
HG 10.0
Frost protection
setting
10 degC
0.05 degC
to 10.0 degC
10
Clr ALL
Restores factory
settings
N/A
Press
& hold OK
11
CLh4
Software version
N/A
None
12
End
Returns display
to Main Screen
N/A
Press OK
Measured
Temperature
Precision:
N/A
Environmental
Operating Temperature:
0°C - 40°C
Shipping and Storage
Temperature:
-10°C to +50°C
Setting Temperature
Range
Anti freeze/OFF:
7°C
Holiday:
0.5°C to 20°C
Timer:
5°C to 35°C
Regulation
Characteristics:
N/A
Electrical
Protection:
Class II - IP30
Power Supply:
2 AAA LR03 1.5V
Operating Life:
Alkaline
2 Years
Output:
N/A
Optional External
Sensor:
N/A
My thermostat doesn’t start
Battery
- Check if the protection sticker
Problem
on the batteries is removed.
- Check the batteries orientation.
-
Check the charge of the batteries.
My thermostat LED, blinks in red
Problem
The logo blinks (ambient sensor)
on Sensors
- Contact your installer.
The logo blinks (floor sensor).
- Check the connection
of the sensor.
- Disconnect the sensor, and check
it with an ohmmeter (the value
must be around 10kohms).
Battery
The logo blinks (batteries)
level is low
- Replace the batteries.
My thermostat seems work correctly but
the temperature in the room was never
in accordance with the program
Program
- Check the clock.
- Check the difference between
Comfort and Setback temperature
is not too high?
- Contact your installer, to check
and adjust the calibration.