Wiring Instructions: 

 

It  is  recommended  that  the  fans  are  connected  into  the  lighting  circuit,  with  double  pole  isolation  (3mm  minimum 
contact separation) provided before the room light switch and suitably fused, in accordance with the latest edition of 
the IEE Wiring Regulations. 
 
Wall mounted fans for fixed wiring should be connected to the power supply through a cable with solid conductors of 
1.0mm² or 1.5mm². 

 

ONLY GTF100LV SELV MODELS ARE SUITABLE FOR SHOWER CUBICLES OR ZONES 1 & 2  
(IN THIS RANGE) 
 
WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK 
 
IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN 

 
SL = 230 Vac Switched Live 

L = 230 Vac Permanent Live 

N = Neutral 

 

 

 
 
 
 

 

 

 

 

 

 

 

                                  
 
 
  Diagram 5   

 

 

 

 

       

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 

 

 
 
 
 

GTF150-S 
GTF150-PC 

Diagram 6 

 

 

GTF150-T 
GTF150-H 