IMPORTANT SAFETY INSTRUCTIONS

When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

READ AND FOLLOW ALL INSTRUCTIONS

Keep for future reference. Failure to follow these warnings and instructions can result in serious injury or death to users, especially children.

NOTICE:

 

CUSTOMERS THAT PURCHASE POOLS MAY BE REQUIRED BY LOCAL OR STATE LAW TO INCUR ADDITIONAL EXPENSES WHEN INSTALLING A POOL, 

IN ORDER TO COMPLY WITH STATE OR LOCAL LAWS REGARDING FENCING AND OTHER SAFETY REQUIREMENTS. CUSTOMERS SHOULD CONTACT THEIR LOCAL 

BUILDING CODE ENFORCEMENT OFFICE FOR FURTHER DETAILS. POLYGROUP

®

 IS NOT RESPONSIBLE FOR ANY ADDITIONAL EXPENSES THAT YOU MAY INCUR.

Safety Care for Children

1. Children, especially children younger than five years, are at high risk of drowning. Drowning occurs silently and quickly and can occur in as little as 2 in (5 cm) of water.

2. Keep children in your direct sight, stay close, and actively supervise them when they are in or near this pool and when you are filling and emptying this pool.

3. When searching for a missing child, check the pool first, even if the child is thought to be in the house.

4. Locate pumps and filters in such a way that children cannot climb on them and gain access to the pool.

5. 

WARNING: 

To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.

Swimming Pool Barriers

Very Important: 

Swimming pool barriers, which restrict access to the pool by small children, may be required by law. A barrier is necessary to provide protection against potential 

drowning and near drowning. Barriers are not a substitute for constant supervision of children. Check state or local laws and codes before setting up pool.

Swimming Pool Equipment

1. The use of artificial pool lighting is at the discretion of the pool owner. Lighting, when installed, should be in accordance with Article 680 of the National Electrical 

    Code (NEC) or its latest approved edition and in consultation with a licensed electrical professional.

2. Keep all electrical lines, radios, speakers, and other electrical appliances away from the pool.

3. Do not place pool near or under overhead electrical lines.

4. All electrical components installed in and/or adjacent to an aboveground/onground residential swimming pool shall be installed in accordance with and shall  

    comply with the requirements of the latest published edition of NFPA 70, National Electrical Code (NEC

®

) Article 680 "Swimming Pools, Fountains, and Similar 

    nstallations", and any state or local code.

Filter Pump Awareness

1.

 WARNING: 

Risk of Electric Shock. Connect only to a grounding type receptacle. This product is provided with a ground-fault circuit-interrupter. If replacement of 

    the plug or cord is needed, use only identical replacement parts.

2.

 WARNING: 

To reduce the risk of electric shock, replace damaged cord immediately.

3.

 WARNING: 

To reduce the risk of electric shock, do not use extension cord to connect unit to electric supply; provide a properly located outlet.

4.

 CAUTION: 

To reduce the risk of electric shock, the pool must be installed no closer than 6 feet (1.8m) from any electrical outlet. Do not place portable appliances 

    closer than 5 feet (1.5m) from the pool.

5.

 CAUTION: 

This pump is for use with storable pools only. Do not use with permanently-installed pools. A storable pool is constructed so that it is capable of being 

    readily disassembled for storage and reassembled to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such that     

    it cannot be readily disassembled for storage.

WARNING 

DO NOT SIT ON

OR LAY OVER

POOL WALL

YOU CAN BE PERMANENTLY

INJURED.

WARNING

AVOID ENTRAPMENT!

STAY AWAY FROM DRAINS & SUCTION

FITTINGS. YOUR HAIR, BODY & JEWELRY

CAN GET SUCKED INTO DRAIN. YOU COULD

BE HELD UNDER WATER & DROWN. DO NOT

USE POOL IF DRAIN OR SUCTION OUTLET

COVER IS MISSING OR BROKEN.

DANGER

PREVENT DROWNING!

CLOSELY WATCH CHILDREN WHO

ARE IN OR NEAR THIS POOL. CHILDREN

UNDER 5 ARE AT HIGHEST RISK FOR

DROWNING. EMPTY POOL OR PREVENT

ACCESS WHEN NOT IN USE.

NO DIVING!

SHALLOW WATER

YOU CAN BREAK

YOUR NECK AND BE

PARALYZED.

OWNER’S MANUAL

3

Содержание SUMMER WAVES RP350

Страница 1: ...nswers to common questions setup videos and troubleshooting tips please visit support polygroupstore com or call Customer Service 1 888 919 0070 To order parts and accessories please visit www polygroupstore com READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE DISTRIBUTED BY Polygroup Trading Limited Unit 606 6th Floor Fairmont House No 8 Cotton Tree Drive Central Hong Kong Should you encount...

Страница 2: ...product in contravention of the manufacturer s Instructions use improper voltage abuse the product in any way or through accident or negligence Normal wear and tear is not covered under this Warranty nor are acts of God outside the control of Polygroup Polygroup will not be held responsible for grasses that may grow through the ground cloth and or pool liner as this is not a manufacturing defect I...

Страница 3: ...latest approved edition and in consultation with a licensed electrical professional 2 Keep all electrical lines radios speakers and other electrical appliances away from the pool 3 Do not place pool near or under overhead electrical lines 4 All electrical components installed in and or adjacent to an aboveground onground residential swimming pool shall be installed in accordance with and shall com...

Страница 4: ...ctions provided for operating the circulation system components 3 All circulation system components and pump that require replacement or servicing shall be installed according to the pump s instruction manual 4 Circulation equipment shall be installed per manufacturer s instructions to provide proper mounting and support to prevent damage from misalignment settlement and vibration and to minimize ...

Страница 5: ...tly below the top rail of the pool 11 Do not use the filter pump during severe weather conditions i e electrical storms tornadoes etc 12 Be aware of overhead power lines when vacuuming your pool or using a telescoping pole 13 Check regularly for signs of wear or loose bolts that could make the deck unsafe 14 Please contact pool site dealer or manufacturer for additional safety signs if deemed nece...

Страница 6: ...ns of access to the pool by young children See the latest published edition of ANSI APSP 8 Model Barrier Code for Residential Swimming Pools Spas and Hot Tubs Barrier Barriers are necessary to provide protection against potential drowning and near drowning and barriers are not a substitute for the constant supervision of children See latest published edition of ANSI APSP 8 Model Barrier Code for R...

Страница 7: ...ridge with a central core mesh divider See page 9 to use the chlorine dispenser DO NOT use this to dispense powdered chlorine shock treatment or any other type of chemicals as damage to the pump filter cartridge and pool will occur 4 The RP Series Filter Pump systems are manufactured by Polygroup and ETL control number 4000608 and 4006317 double insulated and grounded 120 Volts A C 60 Hz All unit ...

Страница 8: ...8 9 7 5 6 24 1 4 8 11 RETURN FITTING 2 24 1 3 4 10 SUCTION FITTING RP350 RP400 23 ...

Страница 9: ...9 OWNER S MANUAL 12 13 14 15 17B 18 16 RP400 24 26 RP350 20A 19A 20B 21 22 19B 24 25 21 22 24 25 12 13 14 15 18 16 24 17A 26 ...

Страница 10: ...the Fitting Gasket with petroleum jelly not included and install the Suction Fitting on the Outlet opening of the pool SETUP INSTRUCTIONS 4 Remove the Filter Pump w Hoses 9 and Hose Clamps q from the package WARNING CLIMBING HAZARD PLEASE PREVENT CHILDREN FROM CLIMBING ON THE FILTER CANISTER TO GAINACCESS TO THE POOL Before assembling your product please take a few minutes to check the contents an...

Страница 11: ...et 7 Tighten all Hose Clamps q to prevent water leakage 9 Air is now trapped inside the Filter Pump system which will prevent the water from flowing smoothly To VENT the system release the trapped air open the Vent Screw e at the top of the pump by turning it counter clockwise The water pressure will force out all the trapped air inside the Filter Pump system Tighten the Vent Screw e when you see ...

Страница 12: ...ours for the filter to fully dry and CAREFULLY BRUSH the pleats to avoid damaging the filter cartridge DO NOT scrub the pleated surface areas Cleaning and scrubbing a filter too vigorously will wear out the cartridge much faster than if it is simply hosed off correctly To ensure pool water stays clean please clean the filter cartridge every day and change when required 14 18 FILTER CARTRIDGE USE C...

Страница 13: ...ILTER ALONE WILL NOT PREVENT ALGAE FROM GROWING IN POOL WATER THIS CAN ONLY BE DONY BE MAINTAINING PROPER CHLORINE AND pH LEVELS AT ALL TIMES Maintain pH level between 7 3 and 7 8 Maintain chlorine level between 1 0 and 1 6 ppm parts per million Superchlorinate your pool at least every other week POOL WATER CARE 1 Check and adjust pH and chlorine levels daily using required chemicals See Section P...

Страница 14: ...ker tripped C Low voltage A Low pool water level A Chlorine level is not in the suitable range B pH level is not in the suitable range C Dirty filter cartridge D Damaged filter cartridge E Slow water flow F Other Chemicals Required G Pool water very dirty B Inlet Outlet clogged C Dirty filter cartridge A Hose area Suction or Return hose does not fit well on canister connections and or wall fitting...

Страница 15: ...er discharge nozzle in the other hand Rotate the nozzle counterclockwise to release the tabs of volute housing from the brackets of pump body 2 Carefully pull upwards once the tabs are clear of the brackets 3 Remove the Volute Housing s and pull out the Rotor Assembly a from the Pump Motor Body p Please be careful as the Rotor Assembly has multiple parts which may come out separately 4 Inspect the...

Страница 16: ...p body 7 Once the rotor has been inserted fasten the volute housing tabs back under the brackets of pump body by turning the volute housing discharge nozzle clockwise 8 Tighten the Volute Housing s With the Volute Cover Screw Set d to complete the reassembly of the pump Motor Assembly 9 Slowly insert the Motor Assembly i back into the Canister u and fasten the Motor Assembly i With Motor Assembly ...

Страница 17: ... Set 4 ea 59 Hose 1 1 4 to 1 1 2 Rubber Fitting Adapter For RP Series Filter Pump sold separately P58PF1520K01 P58281283W05 P58PF1510K01 P58PF1430W05 P58PF2820P01 P58PF7800W05 P58PF7790W05 P58PF0620K01 P58125036W01 P58220221W05 P58534000W05 P58031000K01 P58PF5290W05 P58096000K01 P58530000W05 P53F0350C000 P581041037PR P58050350001 P58PF5270K01 P5816300270B P58030001K01 P58031001K01 P5816400290A P58...

Страница 18: ...nd swimming pool 3 For single drain only Use only ONE outlet fitting for each pump 4 Do not locate this suction outlet fitting on sitting areas or on the backrest for such seating area 5 Install this outlet fitting at location recommended by the pool manufacturer Maximum height 1 8 m from the ground 6 The maximum allowable flow rate of this suction outlet fitting is 24 gallons per minute 1 440 gal...

Страница 19: ...orización de devolución NO DEVUELVA EL PRODUCTO A LA TIENDA Para dudas sobre la instalación o resolución de problemas visite support polygroupstore com Servicio de atención al cliente 1 888 919 0070 Para pedir piezas y accesorios visite www polygroupstore com LEA ESTAS INSTRUCCIONES Y CONSÉRVELAS PARA FUTURAS CONSULTAS DISTRIBUIDO POR Polygroup Trading Limited Unit 606 6th Floor Fairmont House No ...

Страница 20: ...a al comprador original del producto y se limita a la reparación o sustitución del producto a discreción de Polygroup Los daños consiguientes incluidas reclamaciones por pérdidas de agua químicos para piscinas daños o uso no están cubiertos por esta garantía limitada Esta garantía no se considerará válida en caso de modificación o reparación del producto por parte del comprador o de personas no au...

Страница 21: ...a Una vez instalada la iluminación debe cumplir el art 680 del Código Eléctrico Nacional NEC o la última edición aprobada y debe contar con el asesoramiento de un profesional autorizado 2 Mantenga los cables eléctricos radios altavoces y otros aparatos eléctricos legos de la piscina 3 No coloque la piscina cerca o debajo de cables eléctricos 4 Todos los componentes instalados en y o adyacentes a u...

Страница 22: ...ta la pared interior de la piscina Sistemas de circulación 1 Los instaladores deberán seguir las instrucciones escritas relativas a la posición de todos los equipos conectados a los sistemas de circulación 2 El instalador deberá seguir las instrucciones escritas suministradas para utilizar los componentes de los sistemas de circulación 3 Todos los componentes y bombas del sistema de circulación qu...

Страница 23: ...ce bajo la influencia del alcohol o las drogas 9 Existe riesgo de descarga eléctrica si instala la bomba o el filtro en una plataforma La bomba o el filtro podrían caer al agua provocando descargas graves o electrocución 10 No instalar sobre una plataforma u otra superficie en sobre o ligeramente por debajo del riel superior de la piscina 11 No use la bomba de filtro durante condiciones climatológ...

Страница 24: ...SI APSP 8 para piscinas spas y bañeras de hidromasaje de uso residencial Barrera Las barreras son necesarias para ofrecer protección ante posibles ahogamientos y casi ahogamientos y no son un sustituto de la supervisión constante de los niños Véase la última edición publicada del Código sobre dispositivos de seguridad ANSI APSP 8 para piscinas spas y bañeras de hidromasaje de uso residencial Riesg...

Страница 25: ...ts 25 Watts AMPERAJE 0 35 Amps 0 2 Amps LISTA DE PIEZAS PASOS PRELIMINARES NOTASIMPORTANTESACERCADELABOMBADEFILTRACIÓN INFORMACIÓN SOBRE LA POTENCIA DE LA BOMBA DE FILTRACIÓN 1 LEAATENTAMENTE TODAS LAS INSTRUCCIONES y comprenda bien lo que hace falta para montar la bomba de filtración de la serie RP 2 Se recomienda tener a mano un poco de VASELINA no incluida para lubricar las juntas ELEMENTOS NOM...

Страница 26: ...8 9 7 6 24 1 4 8 11 ACCESORIO DE RETORNO 2 24 1 3 4 10 ACCESORIO DE SUCCIÓN RP350 RP400 23 ...

Страница 27: ...MANUAL DEL USUARIO 9 12 13 14 15 17B 18 16 RP400 24 26 RP350 20A 19A 20B 21 22 19B 24 25 21 22 24 25 12 13 14 15 18 16 24 17A 26 ...

Страница 28: ...lina no incluida e instale el accesorio de succión en el orificio de salida de la piscina 4 Saque la bomba de filtración w las mangueras 9 y las abrazaderas de las mangueras q del paquete INSTRUCCIONES DE MONTAJE ADVERTENCIA COLOQUE ESTE PRODUCTOAPARTADO DE LAPISCINAAFIN DE EVITAR QUE LOS NIÑOS SE SUBANAÉLYACCEDANALAPISCINA Antes de montar el producto dedique unos minutos a comprobar el contenido ...

Страница 29: ...brazaderas de la manguera q para evitar la fuga de agua 9 Ahora hay aire atrapado en el sistema de la bomba de filtración lo que evitará que el agua fluya fácilmente Para PURGAR el sistema liberar el aire atrapado abra el tornillo blanco e que está en la parte superior de la bomba girándolo en sentido antihorario La presión del agua hará salir todo el aire atrapado dentro del sistema de la bomba d...

Страница 30: ... el botón de PRUEBA del enchufe del IDTF y desenchúfelo de la salida de la alimentación 5 MUY IMPORTANTE Verifique y ajuste los niveles de cloro y de pH todos los días LA BOMBA DEL FILTRO POR SÍ MISMA NO EVITARÁ QUE CREZCAN ALGAS EN ELAGUA DE LA PISCINA ESTO SOLO PUEDE HACERSE MANTENIENDO NIVELES ADECUADOS DE CLORO Y DE pH EN TODO MOMENTO Para detalles vea CUIDADO DEL AGUA DE LA PISCINA p 13 2 Par...

Страница 31: ...onibles en polygroupstore com o en sus tiendas locales de suministros para piscinas a Kit de prueba para verificar los niveles de cloro y pH del agua de la piscina b Dispensador de cloro flotante no incluido y tableta de cloro para la desinfección del agua y la prevención del crecimiento de algas c Productos químicos de control de pH para ajustar el nivel de pH hacia arriba carbonato de sodio o ha...

Страница 32: ...conectado C Voltaje bajo A El nivel del agua de la piscina es bajo A Los niveles de cloro no se encuentran en el intervalo apropiado B El nivel de pH no está en el intervalo apropiado C El cartucho filtrante está sucio D El cartucho filtrante está dañado E Flujo de agua lento F Hacen falta otros productos químicos G El agua de la piscina está muy sucia B Orificio de entrada salida atascado C El ca...

Страница 33: ...con una mano y la boca de descarga de la voluta con la otra Gire la boca de descarga en sentido antihorario para liberar los resaltes de la voluta de los ganchos de la bomba 2 Tire con cuidado hacia arriba para separar los resaltes de los ganchos 3 Quite la voluta s y tire hacia fuera del rotor a para sacarlo de la carcasa del motor p Tenga cuidado dado que el conjunto del rotor está constituido d...

Страница 34: ...o el rotor asegure de nuevo los resaltes de la voluta a los ganchos de la bomba girando la boca de descarga de la voluta en sentido horario 8 Apriete la voluta s con los tornillos d correspondientes para completar el ensamblaje de la bomba conjunto del motor 9 Introduzca poco a poco el conjunto del motor i en el portafiltro u y asegure el conjunto del motor i con el set de tornillos y arandelas h ...

Страница 35: ...ada de carcasa de voluta Set de tornillos y arandelas del conjunto del motor 4 de cada Manguera de 1 50 m Adaptador de válvula de goma de 1 1 4 a 1 1 2 Se vende por separado para las bombas de filtro de la serie RP P58PF1520K01 P58281283W05 P58PF1510K01 P58PF1430W05 P58PF2820P01 P58PF7800W05 P58PF7790W05 P58PF0620K01 P58125036W01 P58220221W05 P58534000W05 P58031000K01 P58PF5290W05 P58096000K01 P58...

Страница 36: ...l nivel del suelo 3 Solo para drenaje individual Utilice solo UN orificio de salida en cada bomba 4 No coloque este orificio de salida de succión en zonas para sentarse o en el respaldo de dicha zona 5 Instale este orificio de salida en el lugar recomendado por el fabricante de la piscina Altura máxima 1 8 m desde el suelo 6 El caudal máximo permitido de este orificio de salida de succión es de 24...