background image

15

Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8AM to 5PM MST, Monday-Friday.

Extended operating days and hours during peak season requirements.

OWNER’S MANUAL

ASME COMPLIANT SUCTION FITTING INFO

9. PSF-100A or PSF-100B Suction Outlet Fitting is to be replaced every 5 years.

10. No tool is required for installation.

11. Service & winterizing instructions:

      a. CAUTION! DO NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATE: 24 gallons per minute (1,440 gallons per hour)

      b. Carefully observe and inspect the suction outlet fitting for damage and tampering. Missing, broken or cracked suction outlet fitting must be replaced before 

          each use of your pool.

      c. Loose suction outlet fitting should be reattached or replaced before each use of your pool.

      d. Remove and store the suction outlet fitting assembly if temperatures are expected to fall below 32°F (0°C).

1. PSF-100A and PSF-100B Suction Outlet Fitting are certified by IAPMO in accordance with the ASME/ANSI/APSP/ICC-16 2011 

Suction Fittings for Use in 

    Swimming Pools, Wading Pools, Spas, and Hot Tubs.

2. This is a submerged suction outlet fitting for use with aboveground swimming pool.

3. For single drain only. Use only ONE outlet fitting for each pump.

4. Do not locate this suction outlet fitting on sitting areas or on the backrest for such seating area.

5. Install this outlet fitting at location recommended by the pool manufacturer. Maximum height 1.8 m from the ground.

6. The maximum allowable flow rate of this suction outlet fitting is 24 gallons per minute (1,440 gallons per hour).

7. Connection hose:

    a. Model PSF-100A is to be connected with 1 ¼” (31.8mm) diameter hose.

    b. Model PSF-100B is to be connected with 1 ½” (38.1mm) diameter hose.

8. The suction outlet fitting is to be mounted at the suction outlet fitting opening as specified by the manufacturer of the aboveground pool. The diameter of this 

    opening should be within the range of 1.77” to 1.85” (45mm to 47mm). Refer to the following diagram for detailed assembly instructions:

PSF-100A and PSF-100B Suction Outlet Fitting (For Aboveground Pool)

Swimming Pool

Hose

Hose Clamp

Lock Nut, to be tightened by hand

Rubber Gasket

Water Cap, to be installed only 

during pump maintenance 

or filter cartridge replacement

Suction Fitting, PSF-100A 

or PSF-100B

Flat Washer

Содержание SUMMER WAVES CP2000-C

Страница 1: ...ly to the original purchaser of the product and is limited solely to the repair or replacement of the product to be decided in Polygroup s sole discretion Consequential damages including claims for lo...

Страница 2: ...on requirements TABLE OF CONTENTS Warnings Preliminary Steps Important Notes Pump Power Information Parts List Setup Instructions Use of Pump Motor Care Filter Cartridge Pool Maintenance Pool Water Ca...

Страница 3: ...ng when installed should be in accordance with Article 680 of the National Electrical Code NEC or its latest approved edition and in consultation with a licensed electrical professional 2 Keep all ele...

Страница 4: ...quipment connected to the circulation systems 2 The installer shall follow written instructions provided for operating the circulation system components 3 All circulation system components and pump th...

Страница 5: ...r causing severe shock or electrocution 10 Do not install on a deck or other surface at above or slightly below the top rail of the pool 11 Do not use the filter pump during severe weather conditions...

Страница 6: ...ms shall be positioned so as to prevent their being used as a means of access to the pool by young children See the latest published edition of ANSI APSP 8 Model Barrier Code for Residential Swimming...

Страница 7: ...that you have some PETROLEUM JELLY on hand for lubricating the gaskets 1 Installer shall follow written instructions provided for operation of the filter pump systems 2 All electrical components shal...

Страница 8: ...ended operating days and hours during peak season requirements 7 8 6 11 9 20 10 12 23 5 20 2 1 3 4 14 RETURN FITTING SET 13 16 17 18 21 19 15 20 20 SUCTION FITTING SET 22 THE FILTER CARTRIDGE 21 WILL...

Страница 9: ...wall 3 Install the Return Fitting on the Inlet opening of the pool 2 Install the Suction Fitting on the Outlet opening of the pool 4 Remove the Filter Pump Hoses and Hose Clamps from the package SETU...

Страница 10: ...ighten all Hose Clamps to prevent water leakage 14 10 Hand loosen the RF Locking Ring Adjust the Return Fitting Diverter to maximize the circulation of the pool water Hand tighten the RF Locking Ring...

Страница 11: ...pump system vent the filter pump by twisting the Vent Screw counter clockwise 16 1 First turn off and unplug the Power Filter Pump Release the RF Locking Ring Remove the RF Diverter from the Return F...

Страница 12: ...e at polygroupstore com or your local pool supplies stores a Test Kit for checking the chlorine and pH levels of the pool water Use it daily and adjust with the required chemicals b 1 2 54 cm Chlorine...

Страница 13: ...is not cleaning the pool properly e g cloudy green water Water leakage A Fill the pool to the FILL LINE The suction fitting must be at least 4 under water A Maintain chlorine level between 1 0 to 1 6...

Страница 14: ...Screw Vent Screw O Ring Seal Top Canister Gasket Type A C Filter Cartridge O Ring on hose connections 13 14 RF Thrust Washer 12 15 16 17 18 19 20 21 Return Fitting plug RF Plug CP2000 C Complete Filtr...

Страница 15: ...ading Pools Spas and Hot Tubs 2 This is a submerged suction outlet fitting for use with aboveground swimming pool 3 For single drain only Use only ONE outlet fitting for each pump 4 Do not locate this...

Страница 16: ......

Страница 17: ...le de las hierbas que pueden crecer a trav s del pa o de tierra y o el revestimiento de la piscina ya que esto no es un defecto de fabricaci n EN NING N CASO SER N RESPONSABLES Polygroup SUS AGENTES A...

Страница 18: ...e La Potencia De La Bomba Y Lista De Partes Instrucciones De Instalaci n Uso De La Bomba Cuidado Del Motor Y Cartucho Del Filtro Mantenimiento De La Piscina Y Tratamiento Del Agua De La Piscina Gu a P...

Страница 19: ...pamiento de la piscina 1 El uso de iluminaci n artificial para piscinas depende del due o de la piscina Una vez instalada la iluminaci n debe cumplir el art 680 del C digo El ctrico Nacional NEC o la...

Страница 20: ...uir a el cable de alimentaci n de un aparato conectado al recept culo sin penetrar un suelo pared techo marco con puerta abisagrada o corredera apertura de una ventana o cualquier otra barrera permane...

Страница 21: ...entaci n a una toma de corriente con conexi n a tierra 7 Mantenga todos los objetos que se puedan romper fuera de la zona de la piscina 8 El consumo de alcohol no es compatible con las actividades de...

Страница 22: ...na V ase la ltima edici n publicada del C digo sobre dispositivos de seguridad ANSI APSP 8 para piscinas spas y ba eras de hidromasaje de uso residencial Barrera Las barreras son necesarias para ofrec...

Страница 23: ...Empaque para el Cartucho Anillo negro en las conexiones de la manguera Cartucho filtrante tipo A C Cable con el interruptor diferencial Tap n de la boquilla de retorno tap n RF 1 2 3 4 5 6 7 8 9 1 El...

Страница 24: ...ras ampliables durante la temporada alta 7 8 6 11 9 20 10 12 23 5 20 2 1 3 4 14 ACCESORIO DE RETORNO 13 16 17 18 21 19 15 20 20 ACCESORIO DE SUCCI N 22 EL CARTUCHO DEL FILTRO 21 S LO TIENE CAPACIDAD P...

Страница 25: ...rno en el orificio de entrada de la piscina 2 Instale el accesorio de succi n en el orificio de salida de la piscina 4 Saque la bomba de filtraci n las mangueras y las abrazaderas de las mangueras del...

Страница 26: ...e la manguera 13 desde el accesorio de succi n AS hasta la entrada de la bomba 9 Purgue la bomba para liberar el aire atrapado dentro y asegurar un flujo de agua continuo es importante desahogar o des...

Страница 27: ...de utilizar el flujo de retorno como indicador para determinar cu ndo es necesario limpiar el filtro o sustituirlo Si nota que el flujo se reduce l mpielo o sustit yalo 4 Pruebe el agua y ajuste seg n...

Страница 28: ...cina antes de verter las sustancias en ella 6 Averig e la capacidad de agua en galones de su piscina la que se encuentra en el Manual de usuario Tiene que determinar la cantidad de sustancias qu micas...

Страница 29: ...o el disyuntor diferencial no est activado B El tap n del disyuntor diferencial y o el cortocircuito se ha desconectado C Voltaje bajo A El nivel del agua de la piscina es bajo A Nivel de cloro B Niv...

Страница 30: ...blanco Anillo negro para el tornillo Tap n de Sello Empaque para el Cartucho Anillo negro en las conexiones de la manguera Cartucho filtrante tipo A C Tap n uso para servicio solamente Se vende por se...

Страница 31: ...rata de un orificio de salida de succi n sumergido que se utiliza en piscinas por encima del nivel del suelo 3 Solo para drenaje individual Utilice solo UN orificio de salida en cada bomba 4 No coloqu...

Страница 32: ......

Отзывы: