![Polycom Vortex EF2280 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/polycom/vortex-ef2280/vortex-ef2280_reference-manual_1577093029.webp)
LCD M
ENU
S
TRUCTURE
© Polycom, Inc.
27
V
ORTEX
EF2280
Reference Manual
P
ARAMETRIC
EQ M
ENU
The input equalizer is comprised of up to 5 bands of filtering. The whole
group of filters for the channel can also be enabled/disabled without losing
the settings for each band. For each band, you first select the type of filter
from the following: Parametric/Peaking, High Shelf, Low Shelf, Lowpass, or
Highpass.
Parametric/Peaking.
•
Center Frequency: in Hz, between 20 Hz and 20,000 Hz in 1 Hz steps.
•
Bandwidth: in octaves, between 0.05 and 2 octaves in 0.05 octave
steps.
•
Gain: in dB, between -20 and +20 in 1 dB steps.
High Shelf.
•
Center Frequency: in Hz, between 20 Hz and 20,000 Hz in 1 Hz steps.
•
Bandwidth: in dB/octave, between 1 and 24 dB/octave, but is always
less than or equal to 1.2 x Gain.
•
Gain: in dB between -20 and +20 in 1 dB steps.
Low Shelf.
•
Center Frequency: in Hz, between 20 Hz and 20,000 Hz in 1 Hz steps.
•
Bandwidth: in dB/octave, between 1 and 24 dB/octave, but is always
less than or equal to 1.2 x Gain.
•
Gain: in dB between -20 and +20 in 1 dB steps.
Lowpass.
•
Cutoff Frequency: in Hz, between 20 Hz and 20,000 Hz in 1 Hz steps.
Highpass.
•
Cutoff Frequency: in Hz, between 20 Hz and 20,000 Hz in 1 Hz steps.
Linkwitz-Riley Low.
•Frequency: in Hz, between 20 Hz and 20,000 Hz
in 1 Hz steps
•
Slope between 24 dB/oct and 12 dB/oct
Linkwitz-Riley High.
•Frequency: in Hz, between 20 Hz and 20,000 Hz
in 1 Hz steps
•
Slope between 24 dB/oct and 12 dB/oct
Center frequency on Parametric/Peaking is the point with the most (or least)
gain. Bandwidth is the width halfway up the peak (so if the peak is 10 dB, it
is the width between the points where the gain is 5 dB).
Center frequency on shelving filters is the frequency where it crosses the
point halfway between 0 dB and the gain of the filter, halfway up the slope.
Figure 17.
EF2280
Parametric EQ sub-
menu
Parametric EQ
Frequency
Filter Type
Bandwidth
Slope
Gain
Filter Enable
Input/Output EQ
Band
Channel
Содержание Vortex EF2280
Страница 1: ...Vortex EF2280 Reference Manual...
Страница 2: ......
Страница 4: ...VORTEX EF2280 REFERENCE MANUAL Polycom Inc Copyright 2004 2 Technical Support 800 795 9266...
Страница 8: ...INTRODUCTION VORTEX EF2280 Reference Manual 6 Technical Support 800 765 9266...
Страница 12: ...PRE INSTALLATION VORTEX EF2280 Reference Manual 10 Technical Support 800 765 9266...
Страница 20: ...INSTALLATION VORTEX EF2280 Reference Manual 18 Technical Support 800 765 9266...
Страница 42: ...INTEGRATING THE EF2280 INTO YOUR SYSTEM VORTEX EF2280 Reference Manual 40 Technical Support 800 765 9266...
Страница 50: ...TROUBLESHOOTING VORTEX EF2280 Reference Manual 48 Technical Support 800 765 9266...
Страница 58: ...TECHNICAL SPECIFICATIONS VORTEX EF2280 Reference Manual 56 Technical Support 800 765 9266...
Страница 64: ...CONNECTOR PINOUTS VORTEX EF2280 Reference Manual 62 Technical Support 800 765 9266...
Страница 70: ...DEFINITION OF TERMS VORTEX EF2280 Reference Manual 68 Technical Support 800 765 9266...
Страница 74: ...INDEX VORTEX EF2241 Reference Manual 72 Technical Support 800 765 9266...
Страница 75: ......