![Polycom Vortex EF2210 Скачать руководство пользователя страница 92](http://html.mh-extra.com/html/polycom/vortex-ef2210/vortex-ef2210_program-manual_1577716092.webp)
Q01SGMUTE2
Toggle mute on signal generator.
Q01SGMUTEx
, where
x
is
0
or
1
depending on the
current state of the signal generator mute.
Q01SGMUTE?
Query signal generator mute.
Q01SGMUTEx
, where
x
is
0
or
1
depending on the
current state of the signal generator mute.
8.108.
SGTYPE
-- Set Type of Signal Produced by Signal
Generator
This command sets the type of signal produced by the internal signal generator. Setting the type to
0
produces white noise, while setting the type to
1
produces pink noise.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
Description
Status Message
Q01SGTYPE0
Configure signal generator to produce
white noise.
Q01SGTYPE0
Q01SGTYPE1
Configure signal generator to produce
pink noise.
Q01SGTYPE1
Q01SGTYPE?
Query current signal generator type.
Q01SGTYPEx
, where
x
is either
0
or
1
depending on whether the signal generator
is currently configured to generate white or
pink noise, respectively.
8.109.
SSDELAY
-- Set Delay Between Screen Saver
Screens
This command sets or queries the amount of time (in milliseconds) between each new screen of the
LCD screen saver.
This command is an integer command. See
Section 6.2
for more information on this type of
command. The minimum and maximum values for this command are 500 and 600000, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
Description
Status Message
Q01SSDELAY2000
Set screen saver delay to 2
seconds (2000 ms).
Q01SSDELAY2000