ZONEMASTER ZONE SWITCH (TWO ZONE) DAMPER CONTROL SYSTEM 

-

 Operation & Installation Instructions

 4

FIGURE 2 - ZONE NAME STICKER SHEET

FIGURE 1 - Exploded view of touchpad assembly

ZONE NAMES

2 - ZONE LABEL

TOUCHPAD FRONT 

COVER

TOUCHPAD BACK 

COVER

5)  Zoning areas

Air conditioned areas can be zoned according to their functions and 
daily usage such as Family room, Lounge, Library, etc. These zone 
names are chosen as desired. 

IMPORTANT NOTE: The Zone Switch system does not contain 
any safety features to prevent the pressure from building up and 
potentially causing duct damage. Please make sure a separate 
dedicated open spill zone is designed 
with this system to prevent the above 
from occurring.

6)  Touchpad Preparation

 

a) Exploded Diagram  

Figure 1 shows an exploded view of the 
touchpad assembly.

b) Applying Zone Names to Zones 

It is essential to apply correct names  
against the zones to make sure the end 
user is fully aware of the location of  
each zone. The zone names are printed 
on a sticker which is to be peeled off as 
desired and applied in the relevant  
zonename recess on the touchpad. 
There are 31 preset names which can 
be used or personal names can be 
written on the 2 blank stickers provided 
(Figure 2). After applying the zone 
name label on the touchpad, peel off 
the transparent protective covering film 
from the top of the label. 

Содержание Zonemaster Zone Switch

Страница 1: ...ZONE SWITCH TWO ZONE DAMPER CONTROL SYSTEM Operation Installation Instructions www zonemaster com au www polyaire com au 2012 Polyaire Pty Ltd ...

Страница 2: ......

Страница 3: ... Exploded Diagram b Applying Zone names to Zones c Applying 2 zone label 7 Installing the Touchpad 8 Troubleshooting Guide APPENDIX A SPECIFICATIONS APPENDIX B ZONEMASTER CABLE TESTER 3 3 3 3 3 4 4 4 4 5 5 6 7 8 TABLE OF CONTENTS Liability Please read the instructions before installing this Zonemaster Zoning Control System Polyaire Pty Ltd does not accept any responsibility for loss or damage that...

Страница 4: ...N The LED will light up indicating the zone is On Zone Opened The LED will stay on until the zone is turned OFF b Press the zone button again to turn the zone OFF The LED will turn OFF indicating the zone is OFF Zone Closed Note If power fails zones will automatically resume their original position prior to failure once power is returned OPERATION INSTRUCTIONS ZONE BUTTON LED ZONE NMAE LABEL ...

Страница 5: ... zones Dampers are directly connected to the touchpad module LED indicators to show the ON OFF status of the zones Personalised zone labelling using stickers All zones automatically resume their original on off state once powered up after power outage 24 Volt for easy and safe installation and maintenance 3 Components 4 Wiring Schematic NOTE The zones on the touchpad are marked as Z1 and Z2 from t...

Страница 6: ... Please make sure a separate dedicated open spill zone is designed with this system to prevent the above from occurring 6 Touchpad Preparation a Exploded Diagram Figure 1 shows an exploded view of the touchpad assembly b Applying Zone Names to Zones It is essential to apply correct names against the zones to make sure the end user is fully aware of the location of each zone The zone names are prin...

Страница 7: ...overing film from the top of the label 7 Installing the Touchpad a Insert a flat head screw driver into the two gaps at the bottom of the casing and turn the screw driver blade just enough to open the cover as shown in Figure 3 then remove the back cover by sliding it out b Position the back cover on the wall about 1 5m high from the floor and mark the positions for screws and the cut out hole for...

Страница 8: ...eplace the cable Check if the damper motor is faulty by connecting the same zone output port to a spare damper motor If the motor tests faulty replace the damper motor Zones don t open close as desired Check if the damper motor of that particular zone is connected to the right port on the touchpad Damper Motor drives the wrong way Damper blade might be installed in the wrong position If the blade ...

Страница 9: ... Power 24W Components Power Consumption Touchpad 1VA Zone Output Output Voltage 24VAC 50 Hz Current 200mA 1 damper motor Environmental Requirements Operating temperature 0 O C to 60 O C Altitude 0 to 2000 meters Operating relative humidity 10 to 80 Avoid static electricity hazards Avoid electromagnetic radiation sources Avaoid dust contamination Avoid highly corosive environments Maximum Single Ca...

Страница 10: ...before the start of the installation process thus reducing considerable diagnostic time if the fully installed system is subsequently found to have a problem 2 Features of the Cable Tester Tests Centre Latched and Left Latched RJ12 cables Portable quick and easy to test cables Bright LED s to indicate a faulty cable in the dark roof spaces 9V battery operated User Instructions provide Cable Tester...

Страница 11: ...ZONEMASTER ZONE SWITCH TWO ZONE DAMPER CONTROL SYSTEM Operation Installation Instructions 9 ...

Страница 12: ...POLYAIRE PTY LTD 11 13 WHITE ROAD GEPPS CROSS SOUTH AUSTRALIA 5094 TEL 08 8349 8466 FAX 08 8349 8446 www zonemaster com au www polyaire com au ...

Отзывы: