Polon-Alfa TUN-38Ex Скачать руководство пользователя страница 2

2

 

IK

E280

001GB

 

The

 

TUN

38Ex

 

heat

 

detector

 

covered

 

by

 

the

 

present

 

manual,

 

complies

 

with

 

the

 

requirements

 

of

 

the

 

following

 

European

 

Union

 

Directives:

 

 

CPD

  

89/106/EWG

 

on

 

construction

 

materials;

 

LVD

  

2006/96/WE

 

on

 

electric

 

equipment

 

to

 

be

 

used

 

in

 

determined

 

voltage

 

range;

 

EMC

  

2004/108/WE

  

on

 

electromagnetic

 

compatibility;

 

ATEX

  

94/9/WE

  

on

 

equipment

 

and

 

protective

 

systems

 

intended

 

for

 

use

 

in

 

potentially

 

explosive

 

atmospheres.

 

 

The

 

TUN

38Ex

 

Heat

 

Detector

 

has

 

been

 

approved

 

with

 

the

 

EC

Certificate

 

of

 

Conformity

 

No.

 

1438/CPD/0025

 

issued

 

by

 

the

 

Fire

 

Protection

 

Science

 

and

 

Research

 

Centre

 

(CNBOP)

 

Józefów,

 

Poland,

 

a

 

EU

 

notified

 

authority

 

No.

 

1438,

 

confirming

 

its

 

compliance

 

with

 

the

 

requirements

 

of

 

PN

EN

 

54

5:2003

 

standard.

 

 

The

 

Central

 

Mining

 

Institute,

 

Katowice,

 

Poland,

 

a

 

EU

 

notified

 

authority

 

No.

 

1453,

 

has

 

issued

 

the

 

following

 

certificates

 

concerning

 

the

 

TUN

38Ex

 

Heat

 

Detector:

 

‐ 

WE

 

type

 

Inspection

 

Certificate

 

No.

 

KDB

 

04ATEX172X

 

+

 

Supplement

 

No.

 

1

 

‐ 

Quality

 

Assurance

 

Acknowledgement

 

No.

 

GIG

 

04

 

ATEXQ

 

021

 

‐ 

WE

 

Conformity

 

Declaration

 

No.

 

3/E280/2010

 

The

 

Certificates

 

may

 

be

 

downloaded

 

from

 

www.polon

alfa.pl

 

web

 

site.

 

 

 

1438;

 

1453

 

Polon

Alfa

 

Limited

 

Partnership

 

155,

 

Glinki

 

Street,

 

PL

 

85

861

 

Bydgoszcz,

 

POLAND

 

05

 

1438/CPD/0025

 

EN

 

54

5

 

TUN

38Ex

 

Heat

 

Detector

 

(conventional,

 

universal,

 

non

detachable)

 

Application

 

 

fire

 

safety

 

Technical

 

data

 ‐ 

IK

E280

001GB

 

manual

 

 

Read

 

the

 

manual

 

carefully

 

before

 

assembling

 

and

 

operation

 

of

 

the

 

base

 

and

 

the

 

base

 

attachment.

 

Any

 

nonconformity

 

with

 

the

 

instructions

 

contained

 

in

 

the

 

manual

 

may

 

be

 

harmful

 

or

 

may

 

cause

 

violation

 

of

 

the

 

law

 

in

 

force

  

POLON

ALFA

 

bears

 

no

 

responsibility

 

for

 

any

 

damage

 

resulting

 

from

 

usage

 

inconsistent

 

with

 

the

 

manual.

 

 

The

 

product

 

contains

 

parts

 

that

 

can

 

be

 

dangerous

 

for

 

human

 

health.

 

The

 

waste

 

product

 

shall

 

be

 

passed

 

to

 

the

 

nearest

 

waste

 

electric

 

and

 

electronic

 

equipment

 

collection

 

point.

 

 

 
 

NOTE:

 

The

 

manufacturer

 

reserves

 

the

 

right

 

to

 

change

 

specifications

 

of

 

products

 

at

 

any

 

time

 

without

 

prior

 

notice.

 

Содержание TUN-38Ex

Страница 1: ...TUN 38Ex Intrinsically Safe HEAT DETECTOR Installation and Maintenance Manual IK E280 001GB IIIC Issue ...

Страница 2: ...WE type Inspection Certificate No KDB 04ATEX172X Supplement No 1 Quality Assurance Acknowledgement No GIG 04 ATEXQ 021 WE Conformity Declaration No 3 E280 2010 The Certificates may be downloaded from www polon alfa pl web site 1438 1453 Polon Alfa Limited Partnership 155 Glinki Street PL 85 861 Bydgoszcz POLAND 05 1438 CPD 0025 EN 54 5 TUN 38Ex Heat Detector conventional universal non detachable A...

Страница 3: ...nes qualified as 1st and 2nd explosive hazard category resulting from potential explosion danger of explosive gases or inflammable liquid vapours that are ranked at IIA IIB and IIC explosiveness subgroups and T1 up to T6 temperature classes Allowable ambient temperature range 25 C up to 65 C for T6 temperature class 25 C up to 85 C for T1 T5 temperature classes 2 TECHNICAL SPECIFICATIONS Operating...

Страница 4: ...m inner inductance LO 2 5 mH Connecting cable example YnTKSY Core diameter mm 0 8 1 0 Single core resistance Ω km 37 5 24 Pair of cores capacity nF Km 120 120 Inductance mH km 0 7 0 7 Note The total line capacity and line inductance as well as total inner inductance of the detectors installed behind an intrinsically safe barrier of separator must not exceed the level of 110 nF and 2 5 mH As a resu...

Страница 5: ...perational environment this protection assures detector s in proper work explosive atmosphere 6 PRINCIPLES OF OPERATION The TUN 38Ex heat detector reacts to a rise of temperature occurring during initial phase of fire The detector operates as a fixed temperature detector after exceeding its set off operation threshold according to its given class It operates also as a rate of rise heat detector wh...

Страница 6: ...tion Temperature C Maximum Static Activation Temperature C A1 25 50 54 65 B 40 65 69 85 The terms used in the tables have the following meaning Normal Operating Temperature Maximum Operating Temperature maximum temperature level at which detector operates for a short period of time provided no fire hazard occurs Static Activation Temperature temperature level at which detector transmits a warning ...

Страница 7: ...N Determine the detector class with the cramps that are accessible after the cover removal Cramp positions corresponding to various classes is shown on Figure 2 Fig 2 Cramp positioning for various detector class example of A1R H Detectors shall be connected to detecting lines in accordance with Figure 3 ...

Страница 8: ... etc removal periodic device functioning test The TUN 38Ex detector is required to pass periodic controls carried out at least once in 6 months to prove that the detector operates properly and works together with the fire control panel properly Any damaged detector must be passed for repair to the manufacturer During renovation or painting works detectors shall be protected from damage or dirt 9 S...

Страница 9: ...IK E280 001GB 9 Fig 4 TUN 38Ex detector basic dimensions IK E280 001GB 07 2009 ...

Отзывы: