background image

IK-E286-001E 

The EKS-4001 monitoring and controlling element covered by the present manual complies with the 
requirements of the following European Union Directives: 
 

CPD

  

89/106/EWG  on construction materials; 

EMC

   2004/108/WE   on electromagnetic compatibility. 

 
The EKS-4001 element has been approved with the EC-Certificate of Conformity No. 1438/CPD/0071 
issued  by  the  Scientific  and  Research  Centre  for  Fire  Protection 

(CNBOP)  Józefów,  Poland,  a

n  EU 

notified  authority  No.  1438,  confirming  its  compliance  with  the  requirements  of  PN-EN  
54-18:2006 (U) standard. 
 
The certificate may be downloaded from 

www.polon-alfa.pl

 web site.

 

 
 

 

 

1438 

Polon-Alfa 

Spółka z ograniczoną odpowiedzialnością Sp. k.

 

155, Glinki Street, PL 85-861 Bydgoszcz, POLAND 

06 

1438/CPD/0071 

EN 54-18 

Input/output device

  

EKS-4001 addressable monitoring and controlling element 

Technical data - IK-E286-001 manual 

 
 
Read the manual carefully before the detector assembling and commissioning. 

Any  nonconformity  with  the  instructions  contained  in  the  manual  may  be  harmful  or  may  cause 
violation of the law in force  

POLON-ALFA  bears  no  responsibility  for  any  damage  resulting  from  usage  inconsistent  with  the 
manual. 

 

A  waste  product,  unsuitable  for  further  use,  shall  be  passed  to  
a waste electric and electronic equipment collection point. 

 

 

 

NOTE:  The manufacturer reserves the right to change specifications of products at any time 

without prior notice. 

Содержание EKS-4001

Страница 1: ...POLON 4000 INTERACTIVE FIRE DETECTION AND ALARM SYSTEM EKS 4001 MICROPROCESSOR BASED ADDRESSABLE MONITORING AND CONTROLLING ELEMENT Installation and Maintenance Manual IK E286 001E IIIB Edition ...

Страница 2: ...polon alfa pl web site 1438 Polon Alfa Spółka z ograniczoną odpowiedzialnością Sp k 155 Glinki Street PL 85 861 Bydgoszcz POLAND 06 1438 CPD 0071 EN 54 18 Input output device EKS 4001 addressable monitoring and controlling element Technical data IK E286 001 manual Read the manual carefully before the detector assembling and commissioning Any nonconformity with the instructions contained in the man...

Страница 3: ...olled device by line continuity monitoring circuit 615 µA Relay controlling output non potential switchable contact 2 A 30 V Tp relay actuation delay time 2 s 30 s 60 s 90 s Number of monitoring outputs 2 Monitoring lines capacity 65 nF ca 350 m of 1x2x0 8 mm cable Monitoring output initiation NO or NC non potential contact Tk elapsing time after which controlled device monitoring starts no monito...

Страница 4: ...he module with the terminal block in the CUBO S type case The following case sizes are available for one two and four EKS 4001 modules The case bases are drilled in the corners to provide openings for wall mounting Two PG7 cable gland seals are located in the case base side wall in order to insert the detection line inputs and outputs Additionally two or four depending on the case type PG9 cable g...

Страница 5: ...e control panel information about a non maskable fault The way how the monitoring and controlling element works is determined by the element operation mode During the system automatic configuration the default mode settled by the manufacturer is set i e 10000000 in the binary recording 80 in the hexadecimal recording It means that the EKS monitors the controlled device line continuity the relay ac...

Страница 6: ...land seals are properly sealed and unused gland seals are plugged all cable gland seals are plugged by default For installation wires connection a screw driver use is recommended its operation part should be pushed in as far as it goes see below figure into the connector smaller hole Then the wire should be inserted into the bigger hole and the screw driver should be taken off It is advised to use...

Страница 7: ...ld not be exposed to either direct sunlight or heat from heating equipment The EKS 4001 elements storage period in transportation packing should not exceed 6 months The EKS 4001 monitoring and controlling elements should be carried in closed transport means spaces in packing that meets the requirements of transportation regulations in force The temperature during transportation should not be lower...

Страница 8: ...8 IK E286 001E Fig 2 1xEKS case dimensions ...

Страница 9: ...IK E286 001E 9 Fig 3 2xEKS case dimensions ...

Страница 10: ...10 IK E286 001E Fig 4 4xEKS case dimensions ...

Страница 11: ...IK E286 001E 11 Fig 5 Exemplary diagram of EKS 4001 element in 1xEKS case connection in detection line Fig 6 EKS case connection terminals view IK E286 001 03 2009 05 2012 ...