Lone Worker (via software activation)
After active this function, transceiver can alarm and re-
garded as normal alarm if there is no operation within
setted time.
auto-contact (via software activation)
1. Transmitting interval: the time for sending auto
contact among working transceivers.
2. Checking Interval: transceiver will alarm when out
of communication range, if does not receive any
auto contact within setted time .
Power on mode selection
Power on + [sK1] + canale 13.
Enter Wired Clone mode, led indicator lights.
Press PTT to clone, red indicator lights. If red light indica-
tor keeps lighting, that means it fails to communicate.
Then you should press PTT to re-active cloning.
Press [sK1] / [sK2] to quit clone.
It will automatically quit to clone if there is no operation
within 20s.
No transmitting
1. Low voltage: battery voltage is lower than 6.2 V.
2. High Voltage: battery voltage is higher than 9.0 V.
3. No transmitting when busy (Forced to active transmit
if press PTT more than 0.5s within no transmitting 1s).
4. Active again and time is still available after TOT.
Busy state Ignored
With setting prohibited transmitting on busy channel,
press PTT to prohibit transmit when busy communication,
and hear voice prompts.
Release PTT for 1s and press again more than 0.5s, trans-
ceiver will ignore busy state, and force to unreasonable
transmit.
24