![Politec MANA DT SMA Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/politec/mana-dt-sma/mana-dt-sma_installation-and-mounting-manual_1574050021.webp)
Power supply positive
+12/30 Vc
1
12
12/24 Vac (or Vdc)
Heater power supply
24Vac from column power
supply
Power supply negative
GND
2
13
12/24 Vac (or Vdc)
Heater power supply
24Vac from column power
supply
Tamper output
(TMP)
3
14
BARRIER INHIBITION
ON COMMAND
(G.IN)
Bring negative for barrier
inhibition for one minute with
external impulse command .
Reset is automatic after the
elapsed time
Tamper output
A/P
(TMP)
4
15
AND REMOTE
(AND)
+12 Vdc for AND RX1 + RX2
0V for AND RANDOM
Alarm output
(Normally open)
ALARM RELAY
(NO)
5
16
BEAM EXCLUSION
.
+12 Vdc - exclusion RX1
0 V - exclusion RX1 + RX2
Alarm output
(Normally closed)
ALARM RELAY
(NC)
6
17
DISQUALIFICATION
OUTPUT
(S.LOW)
Normal conditions high
impedance;
with fog negative voltage
Alarm output
(Common)
ALARM RELAY
(COM)
7
18
ANTIMASKING
OUTPUT
(A.MASK)
Normal conditions high
impedance;
in case of masking negative
voltage
Input positive
synchronism (TX => RX)
+
SYNCHRONISM
(+ S.IN)
8
19
+ SYNCHRONISM
(+ S.OUT)
Output positive synchronism (TX
=> RX)
Input negative
synchronism (TX => RX)
- SYNCHRONISM
(- S.IN)
9
20
- SYNCHRONISM
(- S.OUT)
Output negative synchronism (TX
=> RX)
Not used
AME COAXIAL
10
21
AME COAXIAL
Not used
Not used
TRESSE COAXIAL
11
22
TRESSE COAXIAL
Not used
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
14.Connections to the MES9C terminal board
21
POLITEC | INSTALLATION MANUAL - VER.3.1
Power supply
Heaters
Input
Synchronism
Output
Synchronism
Power supply
(>12V)
MANA DT SMA