31 

 

 

Figure 10. Window of the applications Settings mode

 

 

 

 

Содержание PM1904A

Страница 1: ...QUICK START OPERATION GUIDE Electronic Personal Dosimeter PM1904 POLISMART II...

Страница 2: ...al operation mode and alarms 13 Recording data to internal memory 15 COMMUNICATION WITH MOBILE DEVICE 16 TROUBLESHOOTING 16 POLISMART MOBILE APPLICATION USER MANUAL 17 Installation of the Application...

Страница 3: ...ating that a radiation source is nearby or a critical dose has been accumulated Users do not need to be experts in health physics to operate this instrument however an understanding of basic principle...

Страница 4: ...l times for proper exposure measurement Please observe all local regulations and safety procedures when working with sources of ionizing radiation Avoid severe mechanical shocks and submerging the ins...

Страница 5: ...pares those measurements to the preset thresholds In the event that thresholds are exceeded PM1904A alerts the user with flashing light signals and audible alarms indicating that a radiation source is...

Страница 6: ...tificate Calibration Certificate Package Specifications Detector type Geiger Muller tube DER Indication range 0 01 Sv h 120 0 mSv h DER Measurement range 1 Sv h 100 0 mSv h DER limit of variation 15 K...

Страница 7: ...0 hours Connectivity PC Mobile Device USB Bluetooth 4 0 LE Environmental temperature range from 20 to 50 C humidity up to 95 at 30 C Ingress protection IP30 Drop test 1 5 m onto concrete surface in PV...

Страница 8: ...USB port to charge the rechargeable battery Green light flashing every 10 seconds the instrument is operating normally and background radiation is below preset thresholds White green light flashing e...

Страница 9: ...ashes every 10 seconds If the light does not flash green but instead flashes white green the battery is partially discharged If there is no light indication on the LED the battery is critically discha...

Страница 10: ...e manufacturer recommends charging PM1904A for 4 hours every month to ensure reliable operation of the instrument for at least 1000 hours and to extend the lifetime of the rechargeable battery NOTE If...

Страница 11: ...t flashing twice every second indicates that the DE threshold was exceeded The manufacturer s preset values are follows DER Threshold 1 1 Sv h DER Threshold 2 10 Sv h DE Threshold 1 1 mSv DE Threshold...

Страница 12: ...d using the POLISMART Mobile Application or the User Software for PC IMPORTANT To set appropriate threshold values and or to get instructions for dealing with any given value of DER DE the user should...

Страница 13: ...the User Software it will automatically synchronize the internal PM1904A clock with the PC or the smartphone It is recommended to synchronize the dosimeter s clock periodically to ensure that the tim...

Страница 14: ...23A BGTBLE112 MIC ID R 209 J00046 BLE112 A KCC CRM BGT BLE112 A POLISMART Mobile App allow the user to set thresholds and data recording intervals synchronize the internal instrument time work with th...

Страница 15: ...mobile devices Via Wi Fi from App Store Open App Store on your mobile device Type polismart in the search box to locate the App Select the POLISMARTprogram from the directory Select INSTALL options En...

Страница 16: ...e downloaded programs Click the iPhone tab In the top menu select the Programs tab and make sure the Sync box is checked Click Apply to synchronize programs with your mobile device The application wil...

Страница 17: ...dosimeter PM1904A and wait up to 10 seconds until the dosimeter name and serial number appear on the screen Select the dosimeter see Figure 2b The main Dashboard screen will appear indicating the cur...

Страница 18: ...appears after detector connection is complete see Figure 3 The measurement error of measured values will be displayed in the middle of the screen to the right of the DER value DER values can be read w...

Страница 19: ...surement mode indication units are Sv h mSv h Sv h or R h mR h R h and DE measurement mode indication units are Sv mSv Sv or R mR R The DE accumulation time is displayed in days hours and minutes Whil...

Страница 20: ...an change DER thresholds enable or disable the sound alarm or restore the default settings The default DER threshold settings are DER Threshold 1 1 Sv h DER Threshold 2 10 Sv h Figure 4 DER Settings f...

Страница 21: ...he user can change DE thresholds enable or disable the sound alarm or restore to default settings The default DE threshold settings are DE Threshold 1 1 mSv DE Threshold 2 5 mSv The Waypoint button al...

Страница 22: ...n to switch the device to Track mode Press the Record button to save tracking records in accordance with track setting as depicted in Figure 5 a b Figure 5 Tracking mode a for smartphone running iOS b...

Страница 23: ...ake considerable time You should wait until the end of the process of reading which is illustrated by circular processing bar The main Sets screen in History mode shows the general dosimetric data for...

Страница 24: ...6 Twitter by pressing the Send button Press the Delete button to clear the screen and the instrument memory The User Software will recommend saving the data Figure 6 History mode on iOS mobile devices...

Страница 25: ...27 Figure 7 History mode on Android OS mobile devices...

Страница 26: ...e displays the map with the waypoints stored in the memory of the mobile application Current user location is marked on the map as a blue point To zoom the map in out double press or slide the fingers...

Страница 27: ...29 a b Figure 9 World Map for Android OS mobile devices...

Страница 28: ...30 Settings mode Press the Settings button to open the Settings mode This mode allows the user to choose following settings...

Страница 29: ...31 Figure 10 Window of the applications Settings mode...

Страница 30: ...rld Map mode settings o Metric the distance measurement units meters shall be adjusted in the Track mode settings and the distance measurement units kilometers shall be adjusted in the World Map mode...

Страница 31: ...e POLISMART application is minimized Import Data downloading function of the radiometric data from Cloud to the smartphone s memory which have been exported as a radiometric data file earlier Reset Hi...

Страница 32: ...el Historic data Auto Load History auto load of the historic radiometric data into the application from the instrument s non volatile memory Clear History after Sync delete the instrument s operation...

Страница 33: ...to the instrument s internal memory The range of the recording interval is from 1 min to 18 hours Recommended recording interval 1 hour or larger Load History the ability to manually loading of the hi...