Ranging (Aim) Lights Adjustment
1. Place the camera onto the test fixture as shown in Figure 3-1.
Figure 3-1 Camera Test Fixture
2. Set the magnification selector knob to its 1X position.
3. Turn on the camera.
4. Press the red shutter button lightly to turn on the range lights. The range
lights should be merged together and centered in the test target (Figure 3-2).
Note:
If the range lights are merged together and centered in the test
target, no adjustment is necessary.
If the range lights are not merged together or centered in the test
target, proceed to step 5 and adjust as needed.
Test Target
area
Camera
Test Fixture
Содержание Macro 5 SLR
Страница 27: ...Repair Manual Macro 5 SLR Camera 27 Section 3 Adjustments Ranging Aim Lights Adjustment 28 Grid Adjustment 31...
Страница 33: ...Repair Manual Macro 5 SLR Camera 33 Section 4 Troubleshooting Diagnostics Module 34...
Страница 63: ...Repair Manual Macro 5 SLR Camera 63 Figure 5 12a Encoder PC Board To J24 on Logic Board Encoder PC Board...
Страница 76: ...Repair Manual Macro 5 SLR Camera 76 Figure 6 1 S1 S2 PC Board...
Страница 77: ...Repair Manual Macro 5 SLR Camera 77 Figure 6 2 Encoder PC Board...
Страница 78: ...Repair Manual Macro 5 SLR Camera 78 Figure 6 3 Trigger PC Board...
Страница 79: ...Repair Manual Macro 5 SLR Camera 79 Figure 6 4 Strobe PC Board 1 of 1...
Страница 80: ...Repair Manual Macro 5 SLR Camera 80 Figure 6 5 Strobe PC Board 2 of 2...
Страница 81: ...Repair Manual Macro 5 SLR Camera 81 Figure 6 6 Logic PC Board 1 of 1...
Страница 82: ...Repair Manual Macro 5 SLR Camera 82 Figure 6 7 Logic PC Board 2 of 2...
Страница 83: ...Repair Manual Macro 5 SLR Camera 83 Figure 6 8 Communication PC Board...