Delay Cycle
Switch Switch
Delay Cycle
Switch Switch
#5
#6
#5
#6
5 Minutes
ON
ON
2 Minutes
ON
OFF
10 Minutes
ON
OFF
5 Minutes
OFF
OFF
20 Minutes
OFF
OFF
10 Minutes
OFF
ON
30 Minutes
OFF
ON
15 Minutes
ON
ON
D. Sensor Located After Sanitizer Introduction
If you are using the controller with an installation where the sen-
sor is located downstream of the introduction of the sanitizer,
there is a potential for the sensor readings to be inaccurate.
Since this installation is generally associated with sanitizer
tablets, which dissolve slowly, it is better to have a long feed
cycle followed by a delay that allows the sanitizer to circulate
past the sensor. This will ensure proper readings from the sen-
sor.
1. Timed Feed Mode = ORP Switch #10 is OFF
2. Feed Cycle in Minutes = ORP Switch #8 is ON
3. Pool Mode = ORP Switch #7 is OFF
Spa Mode = ORP Switch #7 is ON
4. Choose your desired feed and delay cycle times from the fol-
lowing options.
Recommended Settings
ORP SWITCHES ONLY
Feed Cycle
Switch Switch
Delay Cycle
Switch Switch
#3
#4
#5
#6
12 Minutes
OFF
ON
5 Minutes
OFF
OFF
Optional Settings
ORP SWITCHES ONLY
Pool Mode (#7 OFF)
Spa Mode (#7 ON)
Feed Cycle
Switch Switch
Feed Cycle
Switch Switch
#3
#4
#3
#4
12 Minutes
OFF
ON
2 Minutes
OFF
ON
16 Minutes
OFF
OFF
4 Minutes
OFF
OFF
24 Minutes
ON
ON
6 Minutes
ON
ON
32 Minutes
ON
OFF
8 Minutes
ON
OFF
28