- 27 -
3.
While holding the vacuum cleaner by the handle above the trash can, depress the latch on the bottom of the dust collector to open the lid of the dust container and
spill out dust and debris. Close the lid.
Fig. 9
4.
Hold the vacuum cleaner by the handle with the dust container facing down. Drown the release button to detach the dust container, rotate the container at a slight
angle in a clockwise direction, and carefully disconnect it down from the vacuum cleaner. Fig. 10
5.
Pull up and remove the cover with the HEPA filter.
To remove the cyclone filter mesh, turn at a slight angle in a clockwise direction (looking from the bottom) as in figure 1. Then, pulling down, remove the tube of
the secondary cyclone system for cleaning and washing.
Turn the HEPA filter assembly in the direction shown in Figure 2 to separate the filter from the cover. This makes it easier to clean or wash the HEPA filter, see
Fig. 3.
Shake out the dust from the inner cavity of the HEPA filter, gently tapping it with its lower end on a flat non-metallic surface.
Wash the filters thoroughly under a weak stream of running cold water without using detergents and dry them at room temperature. Pay special attention to the
internal cavity of the HEPA filter.
A soft bristle brush (not included) is allowed to wash the plastic housing of the cyclone filter, and the use of detergents is not allowed.
Carefully inspect the elements of the filter system and the HEPA filter. If there are damages, breaks, or deformations, replace the damaged parts.
Attention: do not use a vacuum cleaner with a wet filter, or with a damaged or missing filter.
After cleaning or washing and drying, reassemble the filter system in the reverse order. Fig. 11
6.
To assemble the HEPA filter, use the same steps in the reverse order.
Attention! Do not use force when installing the filter so as not to damage the locking tabs and the filter element.
Install the filter back in the compartment.
Note:
It is necessary to clean the HEPA filter in the above manner after each cleaning. If necessary, replace the filter with a new one (the filter is ordered through an
authorized service center)
Electric brush cleaning
Clean the brush after each cleaning. Avoid severe clogging of the bristle roller.
1. Turn off the device. The adapter must be disconnected from the mains and disconnected from the device.
2. Disconnect the electric brush from the pipe by pressing the lock button.
3. With a small amount of hair and threads wound on the roller, they can be cut with a knife without removing the roller from the brush body.
4. If the bristle roller is heavily clogged, press the latch on the lower surface of the brush in the direction of the arrow, the hatch will rise automatically, remove the hatch
and remove the roller from the brush body. When the roller is removed from the brush body, it can be easily cleaned from the wound hair and threads with a sharp knife
or scissors.
5. Put the bristle roller into place in the brush body in the reverse order.
6. In case of severe clogging of the brush and drive parts, contact an authorized service center for disassembly and cleaning (work related to cleaning parts of a vacuum
cleaner is not included in warranty service).
Maintenance of the wet cleaning nozzle
It is performed after each cleaning.
1. Turn off the appliance.
2. Press the water supply button on the nozzle.
3. Disconnect the nozzle from the electric brush.
4. Open the lid and pour out the remaining water.
5. Remove the cloth and wipe it under a stream of warm water with detergent, dry it.
6. Wipe the nozzle body with a slightly damp wrung-out cloth cloth, dry without heating.
STORAGE
1.
Make sure that the device is unplugged.
2.
Clean the device.
3.
Dry the device and make sure that the device is stored in a dry, cool place.
4.
In case of long-term storage without use, check the battery regularly and charge it if necessary. If the device is not used for a long time, it is recommended to charge
the battery every 3 months, having previously completely discharged it for which it is necessary to start the device in operation for the maximum possible time.
5.
Electrical devices should be stored in a closed, dry and clean room at an ambient temperature of no lower than 5ºС and no higher than 40°C with a relative humidity
of no higher than 70% and no dust, acid or other vapours in the environment that negatively affect the materials of the electrical devices.
TRANSPORTATION
Electrical devices are transported by all means of transport in accordance with the rules for that particular type of carriage of goods in place on a particular type of
transport. When transporting the device, use the original factory packaging.
Transportation of devices should exclude the possibility of direct exposure to atmospheric precipitation and aggressive environments.
Attention! After the end of the service, life does not dispose of the device with household waste. Hand it over to a special collection point for future disposal. This
will help protect the environment.
SALES
Sales rules have not been established.
DISPOSAL REQUIREMENTS
According to WEEE 2012/19/EU on waste electrical and electronic equipment Directive, do not dispose of the devices with the household waste. It should
be transferred to an official separate waste collection center.
TROUBLESHOOTING
This table lists the most common problems that may occur when using the device. If you are unable to solve the problems by your own efforts, contact the customer
support center or an authorized service center.
Trouble symptom
Causes
Troubleshooting
The device does not turn on
The battery is low of charge
Charge the battery
Содержание PVCS 7090 HandStick PRO Aqua
Страница 2: ... 2 1 2 3 4 ...
Страница 3: ... 3 5 6 а b 7 8 ...
Страница 4: ... 4 9 10 11 12 ...
Страница 5: ... 5 13 ...
Страница 60: ......