67
TROUBLESHOOTING
Troubleshooting Symptoms
Engine Will Not Turn Over
Engine Turns Over, but Will Not Start
POSSIBLE CAUSE
SOLUTION
Starter recoil damage
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Low battery voltage
Recharge the battery to 12.8V DC
Starter motor damaged
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Internal engine damage
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
POSSIBLE CAUSE
SOLUTION
Out of fuel
Refuel
Low Oil
Repeat Pre-operation Inspection
Water is present in fuel
Drain the fuel system and refuel
Old or non-recommended
fuel
Drain the fuel system and refuel
Fouled or defective spark
plug
Inspect spark plug and replace if needed
No spark to spark plug
Inspect spark plug, verify engine switch is ON
Water or fuel in crankcase
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Low battery voltage
Recharge the battery to 12.8V DC
Mechanical failure
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
Is the fuel valve on
Turn the fuel valve on.