Polaris PB4SQ Скачать руководство пользователя страница 8

Page 8

Section 7.   PUMP  coMPonentS

 WARNING

To avoid the risk of property damage, severe 

personal injury, and/or death, always 

disconnect the power source before working 

on a motor or its connected load.

 WARNING

To avoid the risk of property damage, severe 

personal injury, and/or death, make sure that 

the control switch or time clock is installed in 

an accessible location so that in the event of 

an equipment failure or a loose plumbing 

fi tting the equipment not be in the same area 

as the pool pump, fi lter, and other equipment.

CAUTION

The pump must be permanently connected to 

a dedicated electrical circuit. No other 

equipment, lights, appliances or outlets may 

be connected to the pump circuit, with the 

exception of devices that may be required to 

operate simultaneously with the pump, such 

as a chlorinating device or heater.

•  Disconnect electrical power to the pump at the breakers.
•  Allow 5 minutes for the capacitor to discharge before servicing.
•  Remove the capacitor housing cover by following steps 1-4 in section 3. 

(R0722900)

•  Disconnect the high voltage wiring as illustrated in the wiring diagram.

1.  Remove the drain plug. 

(R0723100) (R0734300)

a

 Loosen and remove the drain plug and 

drain plug O-ring

c

b

d

Drain Plug O-ring

Wiring For

115v 60hz

Wiring for

230v 60hz

Factory wiring 230V

- White Wire in 8 & 9

- Y

ellow Wire in 7

To change to 

115v

- Move White Wire 

from 9 to 10

- Move

 Y

ellow Wire 

from 7 to 9

BLACK

L1

L2

RED

RED

(CAP)

WHITE

WHITE

BLUE

YELLOW

BLACK

GREEN

GREEN

L1

N

RED

RED

(CAP)

WHITE

WHITE

BLUE

YELLOW

H0540300_REVB

FACT

OR

Y

 WIRING

G

G

a

Drain Plug

& O-ring

Polaris

®

  PB4SQ™ Booster Pump

Содержание PB4SQ

Страница 1: ...must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist I...

Страница 2: ...local government inspection agency Incorrectly installed equipment may fail causing severe injury or property damage WARNING Do not connect the system to an unregulated city water system or other exte...

Страница 3: ...uires adequate ventilation to maintain air temperature at less than the maximum ambient temperature rating listed on the motor rating plate Safety Eye Wear Snap Ring Pliars Adjustable Wrench 9 16 and...

Страница 4: ...ng 1 6 R0722700 Base 1 7 R0747800 Spring Drive Band 1 Ceramic Mating Ring 1 8 R0723200 Spring Drive Band 1 Ceramic Mating Ring 1 Back Plate 1 Pump Housing O Ring 1 Diffuser O Ring First Stage Orange 1...

Страница 5: ...ting device or heater 1 Remove the capacitor housing cover R0722900 a Loosen but do not remove the 4 screws securing the capacitor cover to the capacitor housing b Lift and remove capacitor housing co...

Страница 6: ...may be connected to the pump circuit with the exception of devices that may be required to operate simultaneously with the pump such as a chlorinating device or heater 1 Remove the motor fan cover R0...

Страница 7: ...g forward and tighten the bonding lug screw completely The fan cover should not be able to move forward or backward Tighten the other fastening screw completely Check to ensure the fan cover is not lo...

Страница 8: ...with the exception of devices that may be required to operate simultaneously with the pump such as a chlorinating device or heater Disconnect electrical power to the pump at the breakers Allow 5 minut...

Страница 9: ...ng the pump to normal operation b Insert a standard 1 4 hex key Allen Wrench into the motor shaft through the center of the fan cover mesh The hex key will be used to hold the motor shaft in place whi...

Страница 10: ...ease be sure to follow all reassembly steps 9 11 If any parts do not appear to be in optimal condition it is advised that these parts be replaced before returning the pump to normal operation Ensure t...

Страница 11: ...r wrench secure the pump housing to the pump motor body by using the 4 retaining bolts and washers 11 Install the drain plug R0723100 R0734300 Install the drain plug and drain plug O ring hand tight D...

Страница 12: ...during installation This will ensure a proper water tight seal Thread and tighten the tapered thread of the connector barb into the pump port on the pump body Trim reinforced hose to required length M...

Отзывы: