background image

Содержание GK-Hektor

Страница 1: ......

Страница 2: ...1 ...

Страница 3: ...ntents Contents Contents 2 Components 3 4 User manual 5 7 Transfer from bed 5 Transfer to bed 5 Bathing procedure 6 Cleaning 6 Description of the function 7 Safety instructions 8 Service 9 Technical data 10 ...

Страница 4: ...ponents 3 1 3 8 7 6 4 2 5 Components 1 Pedicure equipment 2 Safety belt 3 Backrest small 4 Push bar 5 Console and battery pack 6 Scale 7 Steerable roller with brake 8 Steerable roller with tracking device ...

Страница 5: ...Components 4 Emergency off button Emergency lower ing button Hand controller with Up Down function Battery pack ...

Страница 6: ...the seat 6 Close the swivel bow 7 Lift the seat 8 Release the locking device 9 Pull lifter and patient away from the bed and transfer to the bathroom Note It is recommended that the patient holds onto the sur rounding rail and the safety strap is fitted during pa tient transport Transfer to bed 1 Lower the lifter onto the upper edge of the mattress 2 Apply the locking device to the wheels 3 Open t...

Страница 7: ...he swivel bow 11 Lower the bath tub completely 12 Release the locking device from the wheels and pull the lifter away from the tub Note When raising the lifter and the bath care must be taken that the patient keeps its arms folded danger of being pinched Cleaning The lifter is cleaned above the bath tub 1 Position the lifter above the bath tub 2 Remove the mattress from the stretcher if available ...

Страница 8: ...he charging current drops below 40mA during the charging process the red LED is extinguished to indicate that the battery is fully charged The charging period lasts at least 12 hours The battery can be re charged at any time After charging remove the plug from mains power supply The red emergency off mushroom button serves down the lifter drive Pressing the mushroom button brings the switch into t...

Страница 9: ...ge at regular intervals regardless of how often it is used We also recommend that you ask our service Department to carry out a safety and functional check at least once every year Note The safety rules and instructions in this operating ma nual must be observed in order to ensure safe and proper use of the equipment Adjustments and repairs must be carried out by authorized and appropriately quali...

Страница 10: ...cted to plug Connect to plug Lifter cannot be moved downwards without applying force Pinching protection has been triggered Gently push the Lifter downwards No movement is possible although the battery is fully charged Defect fuse Unscrew the cap and check the fuse on the electronic Also check the fuse in the battery box Note These tasks must be performed only by trained and authorized personnel m...

Страница 11: ...electric shock Typ B Transport and storage 20 C at 40 C Operating temperature 10 C at 40 C Dimensions 116 x 68 x 95 HxBxT cm EMC tested in accordance with EN 60 601 1 2 Charger Type DL 12 1 Power supply voltage 230V 50Hz Charging power 13 6V 1A Protection class II Loading characteristic IU Protection against ingress of moisture IP 20 Tested in accordance with EN 60 335 2 29 Disposal of the lifter ...