17
RUHOHFWULFDOOLQHQRLVHVXFKDV(0,HOHFWURPDJQHWLFLQWHUIHUHQFH
or
5), UDGLR IUHTXHQF\ LQWHUIHUHQFH PD\ FDXVH HUUDWLF FRQWURO
V\VWHPRSHUDWLRQDQGPDOIXQFWLRQ
$ KLJK TXDOLW\ SRZHU VXSSO\ ¿OWHUVXSSUHVVRU PXVW EH LQVWDOOHG
LI WKH DERYH FRQGLWLRQV H[LVW &DOO WKH WHFKQLFDO VXSSRUW SKRQH
number for more information.
NOTE:
0DOIXQFWLRQVFDXVHGE\WKHSRZHUVXSSO\DQGWKHFRVWV
WR LQVWDOO WKH SRZHU VXSSO\ ILOWHUV DUH QRW FRYHUHG XQGHU WKH
OLPLWHGZDUUDQW\
MIXING VALVES
Water temperature over 125°F (52°C)
can cause severe burns instantly
resulting in severe injury or death.
Children, the elderly and the
physically or mentally disabled are at
highest risk for scald injury.
Feel water before bathing or
showering.
Temperature limiting devices such as
mixing valves must be installed
when required by codes and to
ensure safe temperatures at fixtures.
:DWHUKHDWHGWRDWHPSHUDWXUHZKLFKZLOOVDWLVI\FORWKHVZDVKLQJ
GLVK ZDVKLQJ DQG RWKHU VDQLWL]LQJ QHHGV FDQ VFDOG DQG FDXVH
SHUPDQHQW LQMXU\ XSRQ FRQWDFW 6KRUW UHSHDWHG KHDWLQJ F\FOHV
FDXVHGE\VPDOOKRWZDWHUXVHVFDQFDXVHWHPSHUDWXUHVDWWKHSRLQW
RI XVH WR H[FHHG WKH ZDWHU KHDWHU¶V WHPSHUDWXUH VHWWLQJ E\ XS WR
)&
6RPHSHRSOHDUHPRUHOLNHO\WREHSHUPDQHQWO\LQMXUHGE\KRWZDWHU
WKDQ RWKHUV 7KHVH LQFOXGH WKH HOGHUO\ FKLOGUHQ WKH LQ¿UP DQG WKH
SK\VLFDOO\PHQWDOO\ GLVDEOHG 7DEOH VKRZV WKH DSSUR[LPDWH WLPH
WREXUQ UHODWLRQVKLS IRU QRUPDO DGXOW VNLQ ,I DQ\RQH XVLQJ KRW ZDWHU
SURYLGHG E\ WKH ZDWHU KHDWHU EHLQJ LQVWDOOHG ¿WV LQWR RQH RI WKHVH
JURXSVRULIWKHUHLVDORFDOFRGHRUVWDWHODZUHTXLULQJDFHUWDLQZDWHU
WHPSHUDWXUHDWWKHSRLQWRIXVHWKHQVSHFLDOSUHFDXWLRQVPXVWEHWDNHQ
,Q DGGLWLRQ WR XVLQJ WKH ORZHVW SRVVLEOH WHPSHUDWXUH VHWWLQJ WKDW
VDWLV¿HV WKH GHPDQG RI WKH DSSOLFDWLRQ D 0L[LQJ 9DOYH VKRXOG EH
LQVWDOOHG DW WKH ZDWHU KHDWHU RU DW WKH KRW ZDWHU WDSV WR IXUWKHU
UHGXFHV\VWHPZDWHUWHPSHUDWXUH6HH)LJXUHEHORZDQG)LJXUHV
52 through 54 in Piping Diagrams beginning on Page 58.
HOT WATER
OUTLET
TO TANK
INLET
CHECK
VALVE
MIXING
VALVE
COLD
WATER
INLET
TEMPERED WATER
OUTLET
12” TO 15”
(30-38 cm)
CHECK
VALVE
Figure 8
Mixing valves are available at plumbing supply stores. Consult a
4XDOL¿HG,QVWDOOHURU6HUYLFH$JHQF\)ROORZPL[LQJYDOYHPDQXIDFWXUHU¶V
LQVWUXFWLRQVIRULQVWDOODWLRQRIWKHYDOYHV
,QDOOFDVHVWKHIROORZLQJEXUQWDEOHPXVWEHXVHG
Table 4
Water Temperature
°F (°C)
Time for 1st Degree Burn
(Less Severe Burns)
Time for Permanent
Burns
2nd & 3rd Degree
(Most Severe Burns)
110 (43.3)
QRUPDOVKRZHUWHPS
116 (46.7)
SDLQWKUHVKROG
116 (46.7)
35 minutes
45 minutes
122 (50)
1 minute
5 minutes
131 (55)
VHFRQGV
VHFRQGV
140 (60)
VHFRQGV
VHFRQGV
149 (65)
VHFRQG
VHFRQGV
154 (67.8)
instantaneous
VHFRQG
86*RYHUQPHQW0HPRUDQGXP&36&3HWHU/$UPVWURQJ6HSW
CIRCULATION PUMPS
$FLUFXODWLQJSXPSLVXVHGZKHQDV\VWHPUHTXLUHVDFLUFXODWLQJORRSRU
WKHUHLVDVWRUDJHWDQNXVHGLQFRQMXQFWLRQZLWKWKHZDWHUKHDWHU7KH
WDQNLVSURYLGHGZLWKD´137UHFLUFXODWLRQORRSUHWXUQFRQQHFWLRQ6HH
WKH3LSLQJ'LDJUDPVVHFWLRQEHJLQQLQJRQ3DJHIRUWKHLQVWDOODWLRQ
ORFDWLRQRIFLUFXODWLQJSXPSV
6HH&LUFXODWLRQ3XPS:LULQJ'LDJUDPVRQSDJHIRUHOHFWULFDOKRRNXS
LQIRUPDWLRQ,QVWDOOLQDFFRUGDQFHZLWKWKHFXUUHQWHGLWLRQRI&DQDGLDQ
(OHFWULFDO&RGH&6$&
5HIHUWRWKHFLUFXODWLQJSXPSPDQXIDFWXUHU¶VLQVWUXFWLRQVIRULWVRSHUDWLRQ
OXEULFDWLRQDQGPDLQWHQDQFHLQVWUXFWLRQV