background image

© 2020 Polara    Doc. 350-078-01   Rev. A-25259  02/18/2020    Page 2 of 2

www.polara.com

larger black terminal block labeled BUTTON/PLC. Wire polarity is not important. 

Connect the 3-wire cable to the terminal block on the right. Make sure the 

wiring matches at both ends according to the DAT, GND, and PWR labels at the 

terminals. 

Install iPHCU3S per #2 below.

1.10  With the power on, check that the PBS is operational. Recheck tightness of 

all connections. Re-install the lower cover.

1.11 

  The iNS3 PBS is now ready to use. For programming and configuration of the 

iNS3 PBS, please refer to the “Polara iOS Field Service App User Guide” or 

the “Polara PC App User Guide” in the iNS3 System Manual.

2.  iPHCU3S

Note:  Removing power from the pedestrian signal head during installation is recommended for protection from electric shock.

2.1  The iPHCU3S normally installs inside the Pedestrian Signal Head (PED Head). It is supplied with a hardware kit which includes 

a mounting plate and associated screws and nuts. The photo shows an example of a typical installation. Typically, tapped ¼-20 

holes are present. If they are not, a hole (or holes) to match the mounting plate need to be drilled and tapped. While a single 

screw is sufficient to secure the iPHCU3S bracket to the PED Head, a second screw may be used for additional stability. Distance 

between holes should be 9.3”.
2.1.1  Attach the iPHCU3S to the mounting plate with the supplied hardware. Insert the 6-32 screws and secure with the 6-32 

nuts.

2.1.2  Fasten the assembly to the ped head with the 1/4-20 screws.

2.2  Install jumper wires to connect the light power terminal block to the iPHCU3S input power terminal block. Install jumper wires 

for AC Neutral, Walk, and Don’t Walk. AWG 18 or larger wire is recommended for this installation and should meet all applicable 

regulatory requirements.

2.3  Connect the wires from previously installed 3-wire cable to the output terminal block of the iPHCU3S. 

Once all wire connections 

are made and double-checked for correct landings, restore power to PED Head.

3.  Technical Support Contact

Polara @ 903-366-0300 EXT 4 or 888-340-4872

The latest version of the complete manual is available in PDF format at www.polara.com.

2.1

To PED Call Inputs, 

if available

Ground Screw, must be installed

Ped Head Light Power  Terminal 

Block

WALK

 

DON’T WALK

iPHCU3S

 

AC NEUTRAL

EARTH GND,

if available

iNS3 PBS