background image

6

AU

Telephone Helpline: 1300225960

Technical Specifications

Model

Voltage

Power Current Temperature 

Range

Capacity

(litres)

Refrigerant

Dimensions

H x W x D mm

Weight

(kg)

CM530-A 220-240V~ 

50Hz

230W

1.4A

-24 to -18°C

339

R600a 105g

866 x 1395 x 

741.5

67

CM531-A 220-240V~ 

50Hz

200W

1.3A

-24 to -18°C

462

R290 90g

866 x 1795 x 

741.5

82

CM532-A 220-240V~ 

50Hz

280W

1.8A

-24 to -18°C

523

R290 95g

866 x 1995 x 

741.5

87

Electrical Wiring

The plug is to be connected to a suitable mains socket.

POLAR appliances are wired as follows:

•  Live wire (coloured brown) to terminal marked L

•  Neutral wire (coloured blue) to terminal marked N

•  Earth wire (coloured green/yellow) to terminal marked E

This appliance must be earthed.

If in doubt consult a qualified electrician.

Electrical isolation points must be kept clear of any obstructions. In the event of any emergency 

disconnection being required they must be readily accessible.

Compliance

The product must not be disposed of as household waste. To help prevent possible harm to human 

health and/or the environment, the product must be disposed of in an approved and environmentally safe 

recycling process. For further information on how to dispose of this product correctly, contact the product 

supplier, or the local authority responsible for waste disposal in your area.

POLAR parts have undergone strict product testing in order to comply with regulatory 

standards and specifications set by international, independent, and federal authorities.

POLAR products have been approved to carry the following symbol:

All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, 

mechanical, photocopying, recording or otherwise, without the prior written permission of POLAR.

Every effort is made to ensure all details are correct at the time of going to press, however, POLAR reserve the right to 

change specifications without notice.

CM530-A_CM531-A_CM532-A_A5_v1_20190626.indb   6

2019/6/26   14:55

Содержание CM530-A

Страница 1: ...Model CM530 A CM531 A CM532 A Chest Freezer Instruction manual CM530 A_CM531 A_CM532 A_A5_v1_20190626 indb 1 2019 6 26 14 55 ...

Страница 2: ...ct with the plastic components or door seal Clean immediately if contact occurs Always carry store and handle the appliance in a vertical position and move by holding the base of the appliance Always switch off and disconnect the power supply to the unit before cleaning Keep all packaging away from children Dispose of the packaging in accordance with the regulations of local authorities If the pow...

Страница 3: ...d storage compartments of the appliance unless they are the type recommended by the manufacturer Product Description CM530 A POLAR 385 litre Chest Freezer CM532 A POLAR 587 litre Chest Freezer CM531 A POLAR 516 litre Chest Freezer Introduction Please take a few moments to carefully read through this manual Correct maintenance and operation of this machine will provide the best possible performance...

Страница 4: ...ith feet by default However castors can be supplied as an option Castors can be ordered using the code of AJ450 To replace with the castors follow below steps 1 Remove the feet support 2 Attach the castor support 3 Fix the castor support in place with screws 4 Mount the castor Operation Control Panel RUN indicator Temperature Display Thermostat Storing Food To get the best results from your POLAR ...

Страница 5: ...LAR dealer Fault Probable Cause Solution The appliance is not working The unit is not switched on Check the unit is plugged in correctly and switched on Plug and lead are damaged Call POLAR agent or qualified Technician Fuse in the plug has blown Replace the fuse Power supply Check power supply Internal wiring fault Call POLAR agent or qualified Technician The appliance turns on but the temperatur...

Страница 6: ...e readily accessible Compliance The product must not be disposed of as household waste To help prevent possible harm to human health and or the environment the product must be disposed of in an approved and environmentally safe recycling process For further information on how to dispose of this product correctly contact the product supplier or the local authority responsible for waste disposal in ...

Страница 7: ...010 A1 2013 IEC 60335 2 89 2010 A1 2012 EN 62233 2008 BS EN 55014 1 2017 BS EN 55014 2 2015 BS EN 61000 3 2 2014 BS EN 61000 3 3 2013 Polar 15 Badgally Road Campbelltown NSW 2560 I the undersigned hereby declare that the equipment specified above conforms to the above Legislation and Standard s Date 6th March 2019 Signature Full Name Ashley Hooper Position Technical Quality Manager Responsible Sup...

Страница 8: ...CM530 A_CM531 A_CM532 A_A5_v1_20190626 http www polar refrigerator com CM530 A_CM531 A_CM532 A_A5_v1_20190626 indb 8 2019 6 26 14 55 ...

Отзывы: