Technical Specifications
Electrical Wiring
POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
• Live wire (coloured brown) to terminal marked L
• Neutral wire (coloured blue) to terminal marked N
• Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must
be readily accessible.
Disposal
EU regulations require refrigeration product to be disposed of by specialist companies who remove or recycle all gasses, metal and
plastic components.
Consult your local waste collection authority regarding disposal of your appliance. Local authorities are not obliged to dispose of
commercial refrigeration equipment but may be able to offer advice on how to dispose of the equipment locally.
Alternatively call the POLAR helpline for details of national disposal companies within the EU.
Compliance
The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household
waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in
an approved and environmentally safe recycling process. For further information on how to dispose of this product
correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications
set by international, independent, and federal authorities.
POLAR products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying,
recording or otherwise, without the prior written permission of POLAR.
Every effort is made to ensure all details are correct at the time of going to press, however, POLAR reserve the right to change specifications without
notice.
The appliance is leaking
water
The appliance is not properly levelled
Adjust the screw feet to level the appliance (if applicable)
The discharge outlet is blocked
Clear the discharge outlet
Movement of water to the drain is
obstructed
Clear the floor of the appliance (if applicable)
The water container is damaged
Call POLAR agent or qualified Technician
The drip tray is full
Empty the drip tray (if applicable)
The appliance is
unusually loud
Loose nut/screw
Check and tighten all nuts and screws
The appliance has not been installed in a
level or stable position
Check installation position and change if necessary
Model
Voltage
Power
Current
Temp
Range
Capacity
(litres)
Refrigerant
Dimensions
H x W x D (mm)
Weight
(Kg)
Climatic
Class
CE210
230V 50Hz
230W
1.5A
-25 to -18C
392
R134a 210g
852 x 1331 x 701
63
4
CE211
230V 50Hz
230W
1.5A
-25 to -18C
464
R134a 210g
830 x 1483 x 1603
66
4
CE212
230V 50Hz
230W
2.3A
-25 to -18C
536
R134a 210g
934 x 1603 x 733
85
4