Troubleshooting
If the machine malfunctions due to causes other than those listed or the proposed corrective actions do
not solve the problem please call a Polar agent or qualified technician.
Fault
Probable Cause
Solution
The unit is not working The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug or lead is damaged
Call POLAR agent or qualified Technician
Fuse in the plug has blown
Replace the fuse
Power supply
Check power supply
The appliance is not
cooling
Coolant Leak
Call POLAR agent or qualified technician
Fan Motor Failed
Call POLAR agent or qualified technician
Airflow to the condenser
obstructed
Increase the gap between appliance and
obstacles/heat source
Condenser is clogged
Cleaning the condenser
Loud noises
Appliance is not level
Adjust position to make it level
Appliance is too close to a wall or
other object
Move to a more suitable location
Odour from the unit
Unit is not cleaned for long time
Clean the unit thoroughly
Odour food not properly packed
Seal and pack odour food properly
Error code/
indication
Probable Cause
Solution
“ER1” and
alarm
The evaporator inlet probe is
faulty
Press any button to cease alarm. Call POLAR agent or
qualified Technician to replace the faulty probe
“ER2” and
alarm
The evaporator return gas
probe is faulty
Press any button to cease alarm. Call POLAR agent or
qualified Technician to replace the faulty probe
“ER3” and
alarm
The defrost probe (evaporator
temperature probe) is faulty.
Press any button to cease alarm. Call POLAR agent or
qualified Technician to replace the faulty probe
“ER4” and
alarm
Door not closed properly or
door switch is faulty
Press any button to cease alarm. Close the door/doors
properly or check the door switch
“ER5” and
alarm
Condenser probe is faulty
Press any button to cease alarm. Call POLAR agent or
qualified Technician to replace the faulty probe
“SO” and
alarm
Cabinet temperature probe is
open-circuited
Press any button to cease alarm. Call POLAR agent or
qualified Technician to replace the faulty probe
“SC” and
alarm
Cabinet temperature probe is
short-circuited
Press any button to cease alarm. Call POLAR agent or
qualified Technician to replace the faulty probe
“HI” and alarm Condenser temperature
exceeding 60°C
Power off and re-start machine to cease alarm. Press
power button for 1 second to check the condenser
temperature on the screen. Clean the condenser filter
immediately, or Call POLAR agent or qualified technician