Polar Electro Polar Heat C1 Скачать руководство пользователя страница 5

4

 

Faults & Solutions 

 

4.1 Error Code 

 

Error 
Code 

Error of Issue 

Troubleshooting 

E-01 

The heater failed to 
ignite 

Two ignition failures, check the oil circuit and intake and 
exhaust. 

E-02 

Flame goes out 

The flame goes out during operation, check the oil 
circuit. 

E-03 

The voltage is too high  The voltage is continuously higher than 16V for 5 

seconds 

E-04 

The voltage is too low 

The  voltage  is  continuously  lower  than  10V  for  20 
seconds 

E-05 

Water temperature 
sensor 

Open circuit or short circuit 

E-06 

Overheating sensor 

Open circuit or short circuit 

E-07 

The fuel pump is 
malfunctioning 

Fuel pump open 

E-08 

Fan failure 

Open circuit or short circuit 

E-09 

The glow plug is 
malfunctioning 

Open circuit or short circuit 

E-10 

The glow plug power is 
too small 

The glow plug heat does not reach the set value 

E-11 

The heater is 
overheated 

The water circuit is blocked or the antifreeze is lacking 

E-12 

Overheating lock 
machine 

Three consecutive overheating failures 

E-13 

Ignition fails and locks 
the machine 

The heater fails E-01 twice in a row, and the machine 
locks 

E-14 

Water pump failure 

Short circuit of water pump 

E-15 

Lin communication 
failure 

Lin communication line failure 

 

4.2 Fault solution 

If the heater fails in the power-on state, the screen will show E-XX. Press and hold the 
power-off button for 3 seconds to turn off the heater. 3 seconds later, turn on the heater again 
and the fault code will be cleared. If the fault is not removed, the fault code will still appear until 
the fault is removed. See the fault code table for details. 
If the fault E-12 and E-13 appear, the heater is already in a locked state at this time. Shutdown 
state, you need to pull off the heater fuse (20A) for 3 seconds, and then reinstall the fuse, the 
machine lock-up fault is removed. 

 

Отзывы: