A qualified technician must carry out repairs if required.
Fault
Probable Cause
Solution
The appliance is not
working
The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug or lead is damaged
Replace Plug or lead
Fuse in the plug has blown
Replace the fuse
Mains power supply fault
Check mains power supply
The appliance turns on,
but the temperature is
too high/low
Too much ice on the evaporator
Defrost the appliance
Condenser blocked with dust
Clean the condenser
Doors are not shut properly
Check door is shut and seals are not
damaged
Appliance is located near a
heat source or air flow to the
condenser is being interrupted
Move the refrigerator to a more suitable
location
Ambient temperature is too high
Increase ventilation or move appliance to a
cooler position
Appliance is overloaded
Reduce the amount of medicines stored
The appliance is
leaking water
The appliance is not properly
levelled
Adjust the screw feet to level the appliance
(if applicable)
The discharge outlet is blocked
Clear the discharge outlet
Movement of water to the drain is
obstructed
Clear the floor of the appliance
(if applicable)
The water container is damaged
Replace the water container
The drip tray is overflowing
Empty the drip tray (if applicable)
The appliance is
unusually loud
Loose nut/screw
Check and tighten all nuts and screws
The appliance has not been
installed in a level or stable
position
Check installation position and change if
necessary
on display
Unit in state of “Emergency power
supply” due to power off
Check mains power supply
Technical Specifications
Model
Voltage
Power
Current
Temperature
Range
Net
Capacity Refrigerant
Dimensions
H x W x D mm
Weight
(kg)
FD169 220-240V~
50Hz
150W
0.7A
2°C ~ 8°C
58L
R600a
(55g)
855 x 600 x
595
44